Title: Coherence and phase synchronization: generalization to pairs of multivariate time series, and removal of zero-lag contributions

Abstract: Coherence and phase synchronization between time series corresponding to different spatial locations are usually interpreted as indicators of the connectivity between locations. In neurophysiology, time series of electric neuronal activity are essential for studying brain interconnectivity. Such signals can either be invasively measured from depth electrodes, or computed from very high time resolution, non-invasive, extracranial recordings of scalp electric potential differences (EEG: electroencephalogram) and magnetic fields (MEG: magnetoencephalogram) by means of a tomography such as sLORETA (standardized low resolution brain electromagnetic tomography). There are two problems in this case. First, in the usual situation of unknown cortical geometry, the estimated signal at each brain location is a vector with three components (i.e. a current density vector), which means that coherence and phase synchronization must be generalized to pairs of multivariate time series. Second, the inherent low spatial resolution of the EEG/MEG tomography introduces artificially high zero-lag coherence and phase synchronization. In this report, solutions to both problems are presented. Two additional generalizations are briefly mentioned: (1) conditional coherence and phase synchronization; and (2) non-stationary time-frequency analysis. Finally, a non-parametric randomization method for connectivity significance testing is outlined. The new connectivity measures proposed here can be applied to pairs of univariate EEG/MEG signals, as is traditional in the published literature. However, these calculations cannot be interpreted as connectivity, since it is in general incorrect to associate an extracranial electrode or sensor to the underlying cortex.
Comments: Technical report
Subjects: Methodology (stat.ME); Applications (stat.AP)
Cite as: arXiv:0706.1776 [stat.ME]
  (or arXiv:0706.1776v3 [stat.ME] for this version)

Submission history

From: Roberto D. Pascual-Marqui [view email]
[v1] Tue, 12 Jun 2007 19:48:30 GMT (233kb)
[v2] Wed, 13 Jun 2007 11:35:14 GMT (219kb)
[v3] Thu, 12 Jul 2007 12:24:44 GMT (197kb)

Link back to: arXiv, form interface, contact.