Current browse context:
physics.atom-ph
Change to browse by:
References & Citations
Physics > Atomic Physics
Title: Measurement of Vacuum Pressure with a Magneto-Optical Trap: a Pressure-Rise Method
(Submitted on 30 Jan 2014 (v1), last revised 29 Jan 2015 (this version, v2))
Abstract: The lifetime of an atom trap is often limited by the presence of residual background gases in the vacuum chamber. This leads to the lifetime being inversely proportional to the pressure. Here we use this dependence to estimate the pressure and to obtain pressure rate-of-rise curves, which are commonly used in vacuum science to evaluate the performance of a system. We observe different rates of pressure increase in response to different levels of outgassing in our system. Therefore we suggest that this is a sensitive method which will be useful in applications of cold atom systems, in particular where the inclusion of a standard vacuum gauge is impractical.
Submission history
From: Donatella Cassettari [view email][v1] Thu, 30 Jan 2014 18:33:35 GMT (1146kb,D)
[v2] Thu, 29 Jan 2015 09:38:35 GMT (1157kb)