Current browse context:
physics.med-ph
Change to browse by:
References & Citations
Physics > Medical Physics
Title: Quantitative ultrasound characterization and comparison of healthy and malignant prostate cells
(Submitted on 17 Nov 2019)
Abstract: Speed of sound and attenuation as a function of frequency between 2 and 18 MHz were measured and compared for a cancerous prostate cell line and a healthy prostate cell line. Speed of sound for the cancerous cells line was found to be 1521.4 $\pm$ 0.8~m/s, which was equivalent to the speed of sound for the healthy cell line of 1521.5 $\pm$ 0.6~m/s. The average attenuation coefficient was 0.091 $\pm$ 0.003 $\frac{\rm{dB}}{\rm{cm-MHz}}$ for the cancerous prostate cell line and 0.057 $\pm$ 0.003 $\frac{\rm{dB}}{\rm{cm-MHz}}$ for the healthy prostate cell line, showing a higher attenuation for the cancerous cell line.