Title: Electron beam characterization with beam loss monitors in AWAKE
(Submitted on 24 Nov 2019 (v1), last revised 6 Mar 2020 (this version, v2))
Abstract: We present a method to measure transverse size and position of an electron or proton beam, close to the injection point in plasma wakefields, where other diagnostics are not available. We show that transverse size measurements are in agreement with values expected from the beam optics with a $< 10\%$ uncertainty. We confirm the deflection of the low-energy 18 MeV electron beam trajectory by the Earth's magnetic field. This measurement can be used to correct for this effect and set proper electron bunch injection parameters. The advanced wakefield experiment at CERN (AWAKE) relies on these measurements for optimizing electron injection.
Submission history
From: Livio Verra [view email][v1] Sun, 24 Nov 2019 09:34:22 GMT (461kb,D)
[v2] Fri, 6 Mar 2020 14:43:50 GMT (524kb)