We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

astro-ph.IM

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Astrophysics > Instrumentation and Methods for Astrophysics

Title: Modal noise mitigation for high-precision spectroscopy using a photonic reformatter

Authors: Fraser A. Pike (1), Aurélien Benoît (1), David G. MacLachlan (1), Robert J. Harris (2), Itandehui Gris Sánchez (3 and 4), David Lee (5), Tim A. Birks (3), Robert R. Thomson (1) ((1) Heriot-Watt University, Edinburgh, UK, (2) Zentrum für Astronomie der Universität Heidelberg, Germany, (3) University of Bath, UK, (4) Currently with ITEAM Research Institute, Valencia, Spain, (5) STFC UK Astronomy Technology Centre, UK)
Abstract: Recently, we demonstrated how an astrophotonic light reformatting device, based on a multicore fibre photonic lantern and a three-dimensional waveguide component, can be used to efficiently reformat the point spread function of a telescope to a diffraction-limited psuedo-slit [arXiv:1512.07309]. Here, we demonstrate how such a device can also efficiently mitigate modal noise -- a potential source of instability in high resolution multi-mode fibre-fed spectrographs). To investigate the modal noise performance of the photonic reformatter, we have used it to feed light into a bench-top near-infrared spectrograph (R {\approx} 9,500, {\lambda} {\approx} 1550 nm). One approach to quantifying the modal noise involved the use of broadband excitation light and a statistical analysis of how the overall measured spectrum was affected by variations in the input coupling conditions. This approach indicated that the photonic reformatter could reduce modal noise by a factor of six when compared to a multi-mode fibre with a similar number of guided modes. Another approach to quantifying the modal noise involved the use of multiple spectrally narrow lines, and an analysis of how the measured barycentres of these lines were affected by variations in the input coupling. Using this approach, the photonic reformatter was observed to suppress modal noise to the level necessary to obtain spectra with stability close to that observed when using a single mode fibre feed. These results demonstrate the potential of using photonic reformatters to enable efficient multi-mode spectrographs that operate at the diffraction limit and are free of modal noise, with potential applications including radial velocity measurements of M-dwarfs.
Comments: 13 pages, 9 figures (including appendix)
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM)
DOI: 10.1093/mnras/staa1950
Cite as: arXiv:2001.09211 [astro-ph.IM]
  (or arXiv:2001.09211v1 [astro-ph.IM] for this version)

Submission history

From: Fraser Pike [view email]
[v1] Fri, 24 Jan 2020 22:02:37 GMT (2696kb)

Link back to: arXiv, form interface, contact.