Title: Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture

Authors: L. Rogers, B.J.P. Jones, A. Laing, S. Pingulkar, K. Woodruff, C. Adams, V. Álvarez, L. Arazi, I.J. Arnquist, C.D.R Azevedo, K. Bailey, F. Ballester, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, N. Byrnes, S. Cárcel, J.V. Carrión, S. Cebrián, E. Church, C.A.N. Conde, T. Contreras, G. Díaz, J. Díaz, M. Diesburg, R. Dingler, J. Escada, R. Esteve, R. Felkai, A.F.M. Fernandes, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, S. Ghosh, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R. Guenette, R.M. Gutiérrez, J. Haefner, K. Hafidi, J. Hauptman, C.A.O. Henriques, J.A. Hernando Morata, P. Herrero, V. Herrero, Y. Ifergan, S. Johnston, M. Kekic, L. Labarga, P. Lebrun, N. López-March, M. Losada, R.D.P. Mano, et al. (37 additional authors not shown)
Abstract: \Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
Subjects: Instrumentation and Detectors (physics.ins-det); High Energy Physics - Experiment (hep-ex)
DOI: 10.1088/1361-6471/ab8915
Cite as: arXiv:2001.11147 [physics.ins-det]