Title: Towards windproofing LIGO: Reducing the effect of wind-driven floor tilt by using rotation sensors in active seismic isolation
(Submitted on 13 Mar 2020 (v1), last revised 4 Jun 2020 (this version, v2))
Abstract: Modern gravitational-wave observatories require robust low-frequency active seismic isolation in order to keep the interferometer at its ideal operating conditions. Seismometers are used to measure both the motion of the ground and isolated platform. These devices are susceptible to contamination from ground tilt at frequencies below 0.1 Hz, particularly arising from wind-pressure acting on building walls. Consequently, during LIGO's first observing run both observatories suffered significant downtime when wind-speeds were above 7 m/s. We describe the use of ground rotation sensors at the LIGO Hanford Observatory to correct nearby ground seismometers to produce tilt-free ground translation signals. The use of these signals for sensor correction control improved low-frequency seismic isolation and allowed the observatory to operate under wind speeds as high as $15-20$ m/s.
Submission history
From: Michael Ross P [view email][v1] Fri, 13 Mar 2020 19:03:03 GMT (3357kb,D)
[v2] Thu, 4 Jun 2020 22:07:42 GMT (3077kb,D)