Title: Redundant-Baseline Calibration of the Hydrogen Epoch of Reionization Array

Authors: Joshua S. Dillon, Max Lee, Zaki S. Ali, Aaron R. Parsons, Naomi Orosz, Chuneeta Devi Nunhokee, Paul La Plante, Adam P. Beardsley, Nicholas S. Kern, Zara Abdurashidova, James E. Aguirre, Paul Alexander, Yanga Balfour, Gianni Bernardi, Tashalee S. Billings, Judd D. Bowman, Richard F. Bradley, Phil Bull, Jacob Burba, Steve Carey, Chris L. Carilli, Carina Cheng, David R. DeBoer, Matt Dexter, Eloy de Lera Acedo, John Ely, Aaron Ewall-Wice, Nicolas Fagnoni, Randall Fritz, Steven R. Furlanetto, Kingsley Gale-Sides, Brian Glendenning, Deepthi Gorthi, Bradley Greig, Jasper Grobbelaar, Ziyaad Halday, Bryna J. Hazelton, Jacqueline N. Hewitt, Jack Hickish, Daniel C. Jacobs, Austin Julius, Joshua Kerrigan, Piyanat Kittiwisit, Saul A. Kohn, Matthew Kolopanis, Adam Lanman, Telalo Lekalake, David Lewis, et al. (31 additional authors not shown)
Abstract: In 21 cm cosmology, precision calibration is key to the separation of the neutral hydrogen signal from very bright but spectrally-smooth astrophysical foregrounds. The Hydrogen Epoch of Reionization Array (HERA), an interferometer specialized for 21 cm cosmology and now under construction in South Africa, was designed to be largely calibrated using the self-consistency of repeated measurements of the same interferometric modes. This technique, known as "redundant-baseline calibration" resolves most of the internal degrees of freedom in the calibration problem. It assumes, however, on antenna elements with identical primary beams placed precisely on a redundant grid. In this work, we review the detailed implementation of the algorithms enabling redundant-baseline calibration and report results with HERA data. We quantify the effects of real-world non-redundancy and how they compare to the idealized scenario in which redundant measurements differ only in their noise realizations. Finally, we study how non-redundancy can produce spurious temporal structure in our calibration solutions--both in data and in simulations--and present strategies for mitigating that structure.
Comments: 24 Pages, 19 Figures. Updated to match the accepted MNRAS version
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM); Cosmology and Nongalactic Astrophysics (astro-ph.CO)