Title: Study of Silicon Photomultiplier Performance at Different Temperatures

Abstract: Decreasing the operation temperature of a Silicon Photo-Multiplier (SiPM) leads to a drop in its dark noise. Some experiments consider cold temperatures as an option for low noise applications of SiPM. One of those is the TAO detector, which requires operation at $T\approx -50~^\circ$C. A significant dependence of the Photon Detection Efficiency (PDE) of a SiPM on different temperatures was reported with a drastic drop around this temperature. In this paper, we present studies of performance for two samples of SiPMs from Hamamatsu and AdvanSID(FBK) companies in a broad temperature range. No significant difference for the PDE was observed.
Comments: Keywords: Silicon Photomultiplier - SiPM, Photon Detection Efficiency - PDE, Dark Count Rate - DCR, PDE temperature dependence
Subjects: Instrumentation and Detectors (physics.ins-det); High Energy Physics - Experiment (hep-ex)
DOI: 10.1016/j.nima.2021.165162
Cite as: arXiv:2005.10665 [physics.ins-det]
  (or arXiv:2005.10665v1 [physics.ins-det] for this version)

Submission history