Title: Face Coverings, Aerosol Dispersion and Mitigation of Virus Transmission Risk

Authors: I. M. Viola (1), B. Peterson (1), G. Pisetta (1), G. Pavar (1), H. Akhtar (1), F. Menoloascina (1), E. Mangano (1), K. E. Dunn (1), R. Gabl (1), A. Nila (2), E. Molinari (3 and 4), C. Cummins (5), G. Thompson (6), C. M. McDougall (7), T. Y. M. Lo (7 and 8), F.C. Denison (9), P. Digard (10), O. Malik (11), M. J. G. Dunn (12), F. Mehendale (13) ((1) School of Engineering, University of Edinburgh, UK, (2) Lavision UK Ltd., Bicester, UK, (3) UKRI Centre for Doctoral Training in Biomedical AI, School of Informatics, University of Edinburgh, UK, (4) College of Medical, Veterinary and Life Sciences, University of Glasgow, UK, (5) Maxwell Institute for Mathematical Sciences, and Institute for Infrastructure and Environment, Heriot-Watt University, Edinburgh, UK, (6) Centre for Clinical Brain Sciences, Edinburgh, UK, (7) Paediatric Critical Care Unit, Royal Hospital for Sick Children, Edinburgh, UK, (8) Usher Institute, University of Edinburgh, Edinburgh, UK, (9) The Queens Medical Research Institute Edinburgh BioQuarter, Edinburgh, UK, (10) The Roslin Institute, University of Edinburgh, UK, (11) Department of Anaesthesia, Royal Hospital for Sick Children, Edinburgh, UK, (12) Dept of Critical Care, NHS Lothian, Royal Infirmary of Edinburgh, UK, (13) Global Cleft Lip and Palate Research Programme, Global Health Research Centre, Usher Institute, University of Edinburgh, UK)
Abstract: The SARS-CoV-2 virus is primarily transmitted through virus-laden fluid particles ejected from the mouth of infected people. Face covers can mitigate the risk of virus transmission but their outward effectiveness is not fully ascertained. Objective: by using a background oriented schlieren technique, we aim to investigate the air flow ejected by a person while quietly and heavily breathing, while coughing, and with different face covers. Results: we found that all face covers without an outlet valve reduce the front flow through by at least 63% and perhaps as high as 86% if the unfiltered cough jet distance was resolved to the anticipated maximum distance of 2-3 m. However, surgical and handmade masks, and face shields, generate significant leakage jets that may present major hazards. Conclusions: the effectiveness of the masks should mostly be considered based on the generation of secondary jets rather than on the ability to mitigate the front throughflow.
Subjects: Medical Physics (physics.med-ph); Fluid Dynamics (physics.flu-dyn); Physics and Society (physics.soc-ph)
Journal reference: IEEE Open Journal of Engineering in Medicine and Biology, 2021
DOI: 10.1109/OJEMB.2021.3053215
Cite as: arXiv:2005.10720 [physics.med-ph]