We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

astro-ph.IM

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Astrophysics > Instrumentation and Methods for Astrophysics

Title: ALMA High-frequency Long-baseline Campaign in 2017: A Comparison of the Band-to-band and In-band Phase Calibration Techniques and Phase-calibrator Separation Angles

Abstract: The Atacama Large millimeter/submillimeter Array (ALMA) obtains spatial resolutions of 15 to 5 milli-arcsecond (mas) at 275-950GHz (0.87-0.32mm) with 16km baselines. Calibration at higher-frequencies is challenging as ALMA sensitivity and quasar density decrease. The Band-to-Band (B2B) technique observes a detectable quasar at lower frequency that is closer to the target, compared to one at the target high-frequency. Calibration involves a nearly constant instrumental phase offset between the frequencies and the conversion of the temporal phases to the target frequency. The instrumental offsets are solved with a differential-gain-calibration (DGC) sequence, consisting of alternating low and high frequency scans of strong quasar. Here we compare B2B and in-band phase referencing for high-frequencies ($>$289GHz) using 2-15km baselines and calibrator separation angles between $\sim$0.68 and $\sim$11.65$^{\circ}$. The analysis shows that: (1) DGC for B2B produces a coherence loss $<$7% for DGC phase RMS residuals $<$30$^{\circ}$. (2) B2B images using close calibrators ( $<$1.67$^{\circ}$ ) are superior to in-band images using distant ones ( $>$2.42$^{\circ}$ ). (3) For more distant calibrators, B2B is preferred if it provides a calibrator $\sim$2$^{\circ}$ closer than the best in-band calibrator. (4) Decreasing image coherence and poorer image quality occur with increasing phase calibrator separation angle because of uncertainties in the antenna positions and sub-optimal phase referencing. (5) To achieve $>$70% coherence for long-baseline (16 km) band 7 (289GHz) observations, calibrators should be within $\sim$4$^{\circ}$ of the target.
Comments: 17 Figures, 10 Tables
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM)
Journal reference: 2020ApJS..250...18M
DOI: 10.3847/1538-4365/abab94
Cite as: arXiv:2009.06553 [astro-ph.IM]
  (or arXiv:2009.06553v1 [astro-ph.IM] for this version)

Submission history

From: Luke Maud [view email]
[v1] Mon, 14 Sep 2020 16:28:26 GMT (11029kb)

Link back to: arXiv, form interface, contact.