Current browse context:
physics.ins-det
Change to browse by:
References & Citations
Physics > Instrumentation and Detectors
Title: The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector
(Submitted on 11 Jan 2021 (v1), last revised 17 Dec 2021 (this version, v4))
Abstract: Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.
Submission history
From: Eve Bodnia [view email][v1] Mon, 11 Jan 2021 03:25:28 GMT (3616kb,D)
[v2] Fri, 7 May 2021 13:57:50 GMT (4792kb,D)
[v3] Tue, 7 Sep 2021 15:25:40 GMT (5187kb,D)
[v4] Fri, 17 Dec 2021 02:16:52 GMT (12993kb,D)
Link back to: arXiv, form interface, contact.