We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

q-bio.TO

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Quantitative Biology > Tissues and Organs

Title: Efficient identification of myocardial material parameters and the stress-free reference configuration for patient-specific human heart models

Abstract: Image-based computational models of the heart represent a powerful tool to shed new light on the mechanisms underlying physiological and pathological conditions in cardiac function and to improve diagnosis and therapy planning. However, in order to enable the clinical translation of such models, it is crucial to develop personalized models that are able to reproduce the physiological reality of a given patient. There have been numerous contributions in experimental and computational biomechanics to characterize the passive behavior of the myocardium. However, most of these studies suffer from severe limitations and are not applicable to high-resolution geometries. In this work, we present a novel methodology to perform an automated identification of in vivo properties of passive cardiac biomechanics. The highly-efficient algorithm fits material parameters against the shape of a patient-specific approximation of the end-diastolic pressure-volume relation (EDPVR). Simultaneously, a stress-free reference configuration is generated, where a novel fail-safe feature to improve convergence and robustness is implemented. Only clinical image data or previously generated meshes at one time point during diastole and one measured data point of the EDPVR are required as an input. The proposed method can be straightforwardly coupled to existing finite element (FE) software packages and is applicable to different constitutive laws and FE formulations. Sensitivity analysis demonstrates that the algorithm is robust with respect to initial input parameters.
Comments: This research has received funding from the European Union's Horizon 2020 research and innovation programme under the ERA-NET co-fund action No. 680969 (ERA-CVD SICVALVES) funded by the Austrian Science Fund (FWF), Grant I 4652-B
Subjects: Tissues and Organs (q-bio.TO); Biological Physics (physics.bio-ph); Medical Physics (physics.med-ph)
Cite as: arXiv:2101.04411 [q-bio.TO]
  (or arXiv:2101.04411v2 [q-bio.TO] for this version)

Submission history

From: Christoph M Augustin [view email]
[v1] Tue, 12 Jan 2021 11:18:56 GMT (2303kb,D)
[v2] Thu, 14 Jan 2021 15:33:43 GMT (2303kb,D)

Link back to: arXiv, form interface, contact.