Title: Embedding digital chronotherapy into medical devices -- A canine validation for controlling status epilepticus through multi-scale rhythmic brain stimulation
(Submitted on 7 Jul 2021 (v1), last revised 15 Sep 2021 (this version, v3))
Abstract: Circadian and other physiological rhythms play a key role in both normal homeostasis and disease processes. Such is the case of circadian and infradian seizure patterns observed in epilepsy. In this paper we explore a new implantable stimulator that implements chronotherapy as a feedforward input to supplement both open-loop and closed-loop methods. This integrated algorithm allows for stimulation to be adjusted to the ultradian, circadian and infradian patterns observed in patients through slowly-varying temporal adjustments of stimulation and algorithm sub-components, while also enabling adaption of stimulation based on immediate physiological needs such as a breakthrough seizure or change of posture. Embedded physiological sensors in the stimulator can be used to refine the baseline stimulation circadian pattern as a "digital zeitgeber". This approach is tested on a canine with severe drug-resistant idiopathic generalized epilepsy exhibiting a diurnal pattern correlated with sleep-wake cycles. Prior to implantation, the canine's cluster seizures evolved to status epilepticus (SE) and required emergency pharmacological intervention. The cranially-mounted system was fully-implanted bilaterally into the centromedian nucleus of the thalamus. Using time-based modulation, thalamocortical rhythm-specific tuning of frequency parameters as well as fast-adaptive modes based on activity, the canine experienced no further SE events post-implant as of the time of writing (seven months). Importantly, no significant cluster seizures have been observed either, allowing the reduction of rescue medication. The use of chronotherapy as a feedforward signal to augment adaptive neurostimulators could prove a useful method in conditions where sensitivity to temporal patterns are characteristics of the disease state, providing a novel mechanism for tailoring a more patient-specific therapy approach.
Submission history
From: Mayela Zamora Dr [view email][v1] Wed, 7 Jul 2021 03:18:40 GMT (2815kb,D)
[v2] Thu, 2 Sep 2021 02:48:39 GMT (3051kb,D)
[v3] Wed, 15 Sep 2021 00:19:46 GMT (3051kb,D)
Link back to: arXiv, form interface, contact.