References & Citations
Quantum Physics
Title: Implementation of field two-way quantum synchronization of distant clocks across a 7 km deployed fiber link
(Submitted on 2 Sep 2021 (v1), last revised 24 Dec 2021 (this version, v2))
Abstract: The two-way quantum clock synchronization has been shown not only providing femtosecond-level synchronization capability but also security against symmetric delay attacks, thus becoming a prospective method to compare and synchronize distant clocks with both enhanced precision and security. In this letter, a field test of two-way quantum synchronization between a H-maser and a Rb clock linked by a 7 km-long deployed fiber was implemented. Limited by the frequency stability of the Rb clock, the achieved time stability at 30 s was measured as 32 ps. By applying a fiber-optic microwave frequency transfer technology, the stability was improved by more than one-magnitude to 1.9 ps, even though the number of acquired photon pairs was only 1440 in 30 s due to the low sampling rate of the utilized coincidence measurement system. Such implementation demonstrates the high practicability of two-way quantum clock synchronization method for promoting the field applications.
Submission history
From: Runai Quan [view email][v1] Thu, 2 Sep 2021 08:48:51 GMT (623kb)
[v2] Fri, 24 Dec 2021 07:53:01 GMT (800kb)
Link back to: arXiv, form interface, contact.