Title: Dynamic radiological anthropomorphic thoracic phantom with a deformable chest wall

Authors: Maria Akiki (1 and 2), Fadi Rouphael (1), Mazen Moussallem (1 and 3 and 4) ((1) Centre Hospitalier du Nord, Zgharta, Lebanon, (2) Faculty of Sciences, Lebanese University, Hadath, Lebanon, (3) Radiation Oncology Department, Centre de Traitement Médical du nord, Zgharta, Lebanon, (4) Doctoral School of Sciences and Technology, and Faculty of Public Health, Lebanese University, Tripoli, Lebanon)
Abstract: Purpose: Anthropomorphic phantoms can be used in radiotherapy to confirm dose distributions. In this work, a prototype phantom with a deformable chest wall was created based on real human. Methods: A technique similar to 3-dimensional printing was utilized, which involved collecting computed tomography (CT) images of a patient as a reference, contouring the organs, projecting them onto polystyrene panels, and pouring appropriate material into them. Balloons attached to a ventilator and an air compressor were used to periodically generate a breathing cycle. A silicone tumor was also implanted in the lower lobe of the right balloon to investigate its displacement during respiration. During silent and deep breathing, qualitative and quantitative tests were conducted, and the results were compared to research conducted on real humans. Results: The CT images and the shape of the phantom matches those of the real patient. However, few organs densities can be optimized. The air pressure in the ventilator was so weak that it could only create quiet breathing phantom motion on its own. However, deep breathing phantom motion was obtained manually by only using the air compressor. As a consequence, reproducibility and repeatability studies were done only for quiet breathing and results were acceptable. When compared to the real scenario, the phantom's motion amplitudes were appropriate, except in the lateral direction and abdomen section, near the diaphragm, they were negligible. In addition, the tumor displacement was predominant in the Anterior-Posterior direction rather than the Superior-Inferior direction as it should be. Conclusions: As a prototype, the work was successful, nevertheless, several improvements are required, such as optimization of the shape of the mediastinum and developing a mechanical diaphragm movement system synced with a high-pressure air pump.
Subjects: Medical Physics (physics.med-ph)