We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

physics.med-ph

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Physics > Medical Physics

Title: Deep Learning based Direct Segmentation Assisted by Deformable Image Registration for Cone-Beam CT based Auto-Segmentation for Adaptive Radiotherapy

Abstract: Cone-beam CT (CBCT)-based online adaptive radiotherapy calls for accurate auto-segmentation to reduce the time cost for physicians to edit contours. However, deep learning (DL)-based direct segmentation of CBCT images is a challenging task, mainly due to the poor image quality and lack of well-labelled large training datasets. Deformable image registration (DIR) is often used to propagate the manual contours on the planning CT (pCT) of the same patient to CBCT. In this work, we undertake solving the problems mentioned above with the assistance of DIR. Our method consists of three main components. First, we use deformed pCT contours derived from multiple DIR methods between pCT and CBCT as pseudo labels for initial training of the DL-based direct segmentation model. Second, we use deformed pCT contours from another DIR algorithm as influencer volumes to define the region of interest for DL-based direct segmentation. Third, the initially trained DL model is further fine-tuned using a smaller set of true labels. We found that DL-based direct segmentation on CBCT trained with pseudo labels and without influencer volumes shows poor performance compared to DIR-based segmentation. However, adding deformed pCT contours as influencer volumes in the direct segmentation network dramatically improves segmentation performance, reaching the accuracy level of DIR-based segmentation. The DL model with influencer volumes can be further improved through fine-tuning using a smaller set of true labels. Experiments showed that 7 out of 19 structures have an at least 0.2 Dice similarity coefficient increase compared to DIR-based segmentation. A DL-based direct CBCT segmentation model can be improved to outperform DIR-based segmentation models by using deformed pCT contours as pseudo labels and influencer volumes for initial training, and by using a smaller set of true labels for model fine tuning.
Subjects: Medical Physics (physics.med-ph); Computer Vision and Pattern Recognition (cs.CV)
DOI: 10.1088/1361-6560/acb4d7
Cite as: arXiv:2206.03413 [physics.med-ph]
  (or arXiv:2206.03413v2 [physics.med-ph] for this version)

Submission history

From: Xiao Liang [view email]
[v1] Tue, 7 Jun 2022 16:03:33 GMT (1843kb)
[v2] Mon, 10 Oct 2022 15:11:10 GMT (1761kb)

Link back to: arXiv, form interface, contact.