Title: High Sensitivity real-time VOCs monitoring in air through FTIR Spectroscopy using a Multipass Gas Cell Setup

Authors: A. D'Arco (1 and 2), T. Mancini (2 and 3), M. C. Paolozzi (4), S. Macis (2 and 3), A. Marcelli (2 and 5), M. Petrarca (3 and 6), F. Radica (7), G. Tranfo (8), S. Lupi (2 and 3), G. della Ventura (4 and 9) ((1) INFN-LNF Laboratori Nazionali Frascati, (2) Department of Physics University of Rome "La Sapienza", (3) National Institute for Nuclear Physics section Rome1, (4) Department of Science University Rome Tre, (5) Rome International Centre for Materials Science Superstipes, (6) SBAI Department of Basic and Applied Sciences for Engineering University of Rome "Sapienza", (7) Department of Engineering and Geology University G. d'Annunzio Chieti-Pescara, (8) Department of Occupational and Environmental Medicine Epidemiology and Hygiene INAIL, (9) INGV)
Abstract: Human exposure to Volatile Organic Compounds (VOCs) and their presence in indoor and working environments is recognized as a serious health risk, causing impairment of varying severity. Different detecting systems able to monitor VOCs are available in the market, however they have significant limitations for both sensitivity and chemical discrimination capability. During the last years we studied systematically the use of Fourier Transform Infrared Spectroscopy (FTIR) spectroscopy as an alternative, powerful tool for quantifying VOCs in air. We calibrated the method for a set of compounds (styrene, acetone, ethanol and isopropanol) by using both laboratory and portable infrared spectrometers. The aim was to develop a new, real time and highly sensitive sensor system for VOCs monitoring. In this paper, we improve the setup performance testing the feasibility of using a multipass cell with the aim of extending the sensitivity of this sensor system down to the part per milion (ppb) level. Considering that multipass cells are now available also for portable instruments, this study opens the road for the design of new high-resolution devices for environmental monitoring.
Comments: 17 pages, 9 figures
Subjects: Chemical Physics (physics.chem-ph)
Cite as: arXiv:2207.00340 [physics.chem-ph]
  (or arXiv:2207.00340v1 [physics.chem-ph] for this version)

Submission history

From: Maria Chiara Paolozzi [view email]
[v1] Fri, 1 Jul 2022 11:13:36 GMT (1372kb)

Link back to: arXiv, form interface, contact.