Title: Dual-slope imaging of cerebral hemodynamics with frequency-domain near-infrared spectroscopy
(Submitted on 29 Jul 2022 (v1), last revised 4 Jan 2023 (this version, v2))
Abstract: Significance: This work targets the contamination of optical signals by superficial hemodynamics, which is one of the chief hurdles in non-invasive optical measurements of the human brain.
Aim: To identify optimal source-detector distances for Dual-Slope (DS) measurements in Frequency-Domain (FD) Near-InfraRed Spectroscopy (NIRS) and demonstrate preferential sensitivity of Dual-Slope (DS) imaging to deeper tissue (brain) versus superficial tissue (scalp).
Approach: Theoretical studies (in-silico) based on diffusion theory in two-layered and in homogeneous scattering media. In-vivo demonstrations of DS imaging of the human brain during visual stimulation and during systemic blood pressure oscillations.
Results: The mean distance (between the two source-detector distances needed for DS) is the key factor for depth sensitivity. In-vivo imaging of the human occipital lobe with FD NIRS and a mean distance of 31 mm indicated: (1) greater hemodynamic response to visual stimulation from FD phase versus intensity, and from DS versus Single-Distance (SD); (2) hemodynamics from FD phase and DS mainly driven by blood flow, and hemodynamics from SD intensity mainly driven by blood volume.
Conclusions: DS imaging with FD NIRS may suppress confounding contributions from superficial hemodynamics without relying on data at short source-detector distances. This capability can have significant implications for non-invasive optical measurements of the human brain.
Submission history
From: Giles Blaney Ph.D. [view email][v1] Fri, 29 Jul 2022 16:06:31 GMT (3041kb)
[v2] Wed, 4 Jan 2023 15:00:05 GMT (1878kb)