We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

astro-ph.CO

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Astrophysics > Cosmology and Nongalactic Astrophysics

Title: An updated measurement of the Hubble constant from near-infrared observations of Type Ia supernovae

Abstract: We present a measurement of the Hubble constant ($H_0$) using type Ia supernova (SNe Ia) in the near-infrared (NIR) from the recently updated sample of SNe Ia in nearby galaxies with distances measured via Cepheid period-luminosity relations by the SHOES project. We collect public near-infrared photometry of up to 19 calibrator SNe Ia and further 57 SNe Ia in the Hubble flow ($z>0.01$), and directly measure their peak magnitudes in the $J$ and $H$ band by Gaussian processes and spline interpolation. Calibrator peak magnitudes together with Cepheid-based distances are used to estimate the average absolute magnitude in each band, while Hubble-flow SNe are used to constrain the zero-point intercept of the magnitude-redshift relation. Our baseline result of $H_0$ is $72.3\pm1.4$ (stat) $\pm1.4$ (syst) km s$^{-1}$ Mpc$^{-1}$ in the $J$ band and $72.3\pm1.3$ (stat) $\pm1.4$ (syst) km s$^{-1}$ Mpc$^{-1}$ in the $H$ band, where the systematic uncertainties include the standard deviation of up to 21 variations of the analysis, the 0.7\% distance scale systematic from SHOES Cepheid anchors, a photometric zeropoint systematic, and a cosmic variance systematic. Our final measurement represents a measurement with a precision of 2.8\% in both bands. The variant with the largest change in $H_0$ is when limiting the sample to SNe from CSP and CfA programmes, noteworthy because these are the best calibrated, yielding $H_0\sim75$ km s$^{-1}$ Mpc$^{-1}$ in both bands. We demonstrate stretch and reddening corrections are still useful in the NIR to standardize SN Ia NIR peak magnitudes. Based on our results, in order to improve the precision of the $H_0$ measurement with SNe Ia in the NIR in the future, we would need to increase the number of calibrator SNe Ia, be able to extend the Hubble-Lema\^itre diagram to higher-z, and include standardization procedures to help reducing the NIR intrinsic scatter.
Comments: 15 pages, 8 figures. Accepted in A&A
Subjects: Cosmology and Nongalactic Astrophysics (astro-ph.CO)
Journal reference: A&A 679, A95 (2023)
DOI: 10.1051/0004-6361/202244893
Cite as: arXiv:2209.02546 [astro-ph.CO]
  (or arXiv:2209.02546v2 [astro-ph.CO] for this version)

Submission history

From: Lluís Galbany [view email]
[v1] Tue, 6 Sep 2022 14:56:01 GMT (10699kb,D)
[v2] Mon, 18 Sep 2023 08:44:16 GMT (13510kb,D)

Link back to: arXiv, form interface, contact.