Title: Operation Modes of the KATRIN Experiment Tritium Loop System using $^{83\mathrm{m}}$Kr
(Submitted on 28 Sep 2022 (v1), last revised 1 Dec 2022 (this version, v5))
Abstract: The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable $^{83\mathrm{m}}$Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of $^{83\mathrm{m}}$Kr allow a direct access to the starting conditions of $\beta$-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of $^{83\mathrm{m}}$Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable $^{83\mathrm{m}}$Kr-rates, gas densities, and gas compositions inside the WGTS.
Submission history
From: Alexander Marsteller [view email][v1] Wed, 28 Sep 2022 08:58:12 GMT (8497kb,D)
[v2] Thu, 29 Sep 2022 06:35:15 GMT (8497kb,D)
[v3] Tue, 1 Nov 2022 23:06:15 GMT (8485kb,D)
[v4] Wed, 30 Nov 2022 18:45:10 GMT (8677kb,D)
[v5] Thu, 1 Dec 2022 18:46:09 GMT (8677kb,D)