We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

physics.med-ph

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Physics > Medical Physics

Title: Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources

Abstract: PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary and Scatter Separated (PSS) dose tables, and mean photon energies escaping each source. The database also documents the source models which will be freely distributed with egs_brachy. ACQUISITION AND VALIDATION METHODS: Datasets are calculated after a recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air kerma per history is calculated in a 10x10x0.05 cm3 voxel located 100 cm from the source along the transverse axis and then corrected for the lateral and thickness dimensions of the scoring voxel to give the air kerma on the central axis at a point 100cm from the source's mid-point. Full-scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. For validation, data are compared to those from CLRP_TG43v1 and published data. DATA FORMAT AND ACCESS: Data are available at this https URL or this http URL POTENTIAL APPLICATIONS: The CLRP_TG43v2 database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more precise and in some cases more accurate Monte Carlo TG-43 dose calculation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy.
Comments: 28 pages, 11 figures
Subjects: Medical Physics (physics.med-ph)
DOI: 10.1002/mp.16176
Cite as: arXiv:2212.03948 [physics.med-ph]
  (or arXiv:2212.03948v1 [physics.med-ph] for this version)

Submission history

From: Rowan Thomson [view email]
[v1] Wed, 7 Dec 2022 20:46:23 GMT (205kb,D)

Link back to: arXiv, form interface, contact.