We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

cond-mat

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Condensed Matter > Soft Condensed Matter

Title: Tortuosity Measurement and the Effects of Finite Pulse Widths on Xenon Gas Diffusion NMR Studies of Porous Media

Abstract: We have extended the utility of NMR as a technique to probe porous media structure over length scales of ~ 100 - 2000 micron by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous media. We utilized Pulsed Gradient Spin Echo NMR measurements of the time-dependent diffusion coefficient, D(t) of the xenon gas filling the pore space to study further the measurements of both the surface area-pore volume ratio, S/Vp, and the tortuosity (pore connectivity) of the medium. In uniform-size glass bead packs, we observed D(t) decreasing with increasing t, reaching an observed asymptote of ~ 0.62 - 0.65D0, that could be measured over diffusion distances extending over multiple bead diameters. Measurements of D(t)/D0 at differing gas pressures showed this tortuosity limit was not affected by changing the characteristic diffusion length of the spins during the diffusion encoding gradient pulse. This was not the case at the short time limit, where D(t)/D0 was noticeably affected by the gas pressure in the sample. Increasing the gas pressure, and hence reducing D0 and the diffusion during the gradient pulse served to reduce the previously observed deviation of D(t)/D0 from the S/Vp relation. The Pade approximation is used to interpolate between the long and short time limits in D(t). While the short time D(t) point lay above the interpolation line in the case of small beads, due to diffusion during the gradient pulse on the order of the pore size, it was also noted that the experimental D(t) data fell below the Pade line in the case of large beads, most likely due to finite size effects.
Comments: single pdf file containing all figures
Subjects: Soft Condensed Matter (cond-mat.soft); Materials Science (cond-mat.mtrl-sci)
Journal reference: Magnetic Resonance Imaging 19, 345 (2001)
Cite as: arXiv:cond-mat/0211184 [cond-mat.soft]
  (or arXiv:cond-mat/0211184v1 [cond-mat.soft] for this version)

Submission history

From: Ross Mair [view email]
[v1] Sun, 10 Nov 2002 00:51:19 GMT (71kb)

Link back to: arXiv, form interface, contact.