References & Citations
Condensed Matter > Other Condensed Matter
Title: X-ray Resonance in Crystal Cavities--Realization of Fabry-Perot Resonator for Hard X-rays
(Submitted on 17 Dec 2004)
Abstract: X-ray back diffraction from monolithic two silicon crystal plates of 25--150 um thick and a 40--150 um gap using synchrotron radiation of energy resolution deltaE=0.36 meV at 14.4388 keV shows clearly resonance fringes inside the energy gap and the total-reflection range for the (12 4 0) reflection. This cavity resonance results from the coherent interaction between the X-ray wavefields generated by the two plates with a gap smaller than the X-ray coherence length. This finding opens up new opportunities for high-resolution and phase-contrast X-ray studies, and may lead to new developments in X-ray optics.
Link back to: arXiv, form interface, contact.