We gratefully acknowledge support from
the Simons Foundation and member institutions.

Instrumentation and Detectors

New submissions

[ total of 11 entries: 1-11 ]
[ showing up to 2000 entries per page: fewer | more ]

New submissions for Fri, 3 Apr 20

[1]  arXiv:2004.00712 [pdf, other]
Title: Automated laser induced damage threshold testing applied to a ferroelectric spatial light modulator
Subjects: Instrumentation and Detectors (physics.ins-det)

Laser Induced Damage Thresholds (LIDTs) are a measure of the level of fluence an optical component may be expected to handle without observable damage. In this work we present an automated system for measurement of LIDTs for a wide range of components and include details of the data handling, image processing and code required. We then apply this system to LIDT measurements of a commercial HDP-1280-2 'BlueJay' ferroelectric display finding a LIDT of 9.2 W/cm2 {\O}27{\mu}m, 5.5 W/cm2 {\O}150{\mu}m and 3.2 W/cm2 {\O}3.1mm with wavelength 1090+-5nm. Finally, the quality of the results obtained are discussed and conclusions drawn.

[2]  arXiv:2004.00736 [pdf, other]
Title: Characterization of sputtered hafnium thin films for high quality factor microwave kinetic inductance detectors
Comments: 9 pages, 8 figures, 1 table. Submitted to SUST
Subjects: Instrumentation and Detectors (physics.ins-det); Instrumentation and Methods for Astrophysics (astro-ph.IM)

Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 \mu \Omega. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, we study how sputter conditions and especially the power applied to the target during the deposition, affect the hafnium $T_{C}$, resistivity, stress, texture and preferred crystal orientation. We find that the position of the target with respect to the substrate strongly affects the orientation of the crystallites in the films and the internal quality factor, $Q_{i}$, of MKIDs fabricated from the films. In particular, we demonstrate that a DC magnetron sputter deposition at a normal angle of incidence, low pressure, and low plasma power promotes the growth of compressive (002)-oriented films and that such films can be used to make high quality factor MKIDs with $Q_{i}$ up to 600,000.

[3]  arXiv:2004.00851 [pdf, other]
Title: Versatile systems for characterization of large-area silicon pad sensors for highly-granular calorimetry
Subjects: Instrumentation and Detectors (physics.ins-det)

High-granularity calorimeters utilizing silicon pad sensors as main active material are being designed for the CMS endcap calorimeter upgrade and have been proposed for the electromagnetic calorimeters at CLIC, ILC and FCC-ee. The silicon sensors in such experiments are foreseen to cover a very large area of O(1000 $\mathrm{m^2}$). They are typically produced from 6- or 8-inch wafers and consist of a few hundred smaller cells, each with an area of O(0.1 to 1.1 $\mathrm{cm^2}$). Currently the CMS endcap calorimeter upgrade is in a prototyping phase with the aim of choosing the final sensor design. Flexible systems are needed for quick sensor characterization as close as possible to operating conditions, for testing different prototypes and for quality control during mass production. The ARRAY system consists of an active switching matrix PCB with 512 input channels and a passive probe card specific for each sensor layout prototype. The probe card makes contact with each individual pad through spring-loaded pins. ARRAY is designed to measure the leakage current and capacitance per-cell for different bias voltages, keeping the entire sensor area under bias. The Hexaboard probe card follows a similar principle: readout electronics foreseen to be used in the final CMS detector are mounted on a PCB that makes contact with the sensor through spring-loaded pins. It is used to perform noise and charge collection efficiency measurements with irradiated sensors without the need for module assembly. We present the design of the ARRAY and Hexaboard systems as well as measurements performed on different CMS prototype silicon sensors. We also compare the results with alternative multi-needle setups.

[4]  arXiv:2004.00913 [pdf, other]
Title: Status of the PANDA Barrel DIRC
Comments: 7 pages, 5 figures
Subjects: Instrumentation and Detectors (physics.ins-det)

The PANDA experiment will use cooled antiproton beams with high intensity stored1 in the High Energy Storage Ring at FAIR. Reactions on a fixed target producing charmed hadrons will shed light on the strong QCD. Three ring imaging Cherenkov counters are used for charged particle identification. The status of the Barrel DIRC (Detection of Internally Reflected Cherenkov light) is described. Its design is robust and its performance validated in experiments with test beams. The PANDA Barrel DIRC has entered the construction phase and will be installed in 2023/2024.

[5]  arXiv:2004.00937 [pdf]
Title: Determination of the Energy Characteristics of an Electron Beam using a Light Scintillator
Comments: 11 pages, 10 figures, 5 references , scientific article
Subjects: Instrumentation and Detectors (physics.ins-det); High Energy Physics - Experiment (hep-ex)

The possibility of using the effect of full energy absorption in a light scintillator when an electron beam passes through it to determine the energy characteristics of a low and medium energy beam (the absorbed energy method) is experimentally presented. The energy calibration of the quasi-monochromatic electron beam of the Pakhra accelerator of the P. N. Lebedev Physical Institute of the Russian Academy of Sciences using scintillation detectors with a thickness of 14.5, 20, 23.5 and 51.2 cm was performed. For electron beam energies up to about 100 MeV and scintillation detector thicknesses from 5 to 20 cm the accuracy of electron beam energy determination was 10 to 20%, respectively.

[6]  arXiv:2004.00985 [pdf]
Title: Cryogenic phonon-scintillation detectors with PMT readout for rare event search experiments
Journal-ref: Astroparticle Physics, 79 (2016) 31-40
Subjects: Instrumentation and Detectors (physics.ins-det); Instrumentation and Methods for Astrophysics (astro-ph.IM)

Cryogenic phonon-scintillation detectors (CPSD) for rare event search experiments require reliable, efficient and robust photon detectors that can resolve individual photons in a scintillation event.

Cross-lists for Fri, 3 Apr 20

[7]  arXiv:2004.00741 (cross-list from physics.flu-dyn) [pdf]
Title: Evaluation of laser diffraction-based particle size measurements using digital inline holography
Subjects: Fluid Dynamics (physics.flu-dyn); Instrumentation and Detectors (physics.ins-det); Optics (physics.optics)

The measurements of size distribution of small particles (e.g. dusts, droplets, bubbles, etc.) are critical for a broad range of applications in environmental science, public health, industrial manufacturing, etc. Laser diffraction (LD), a widely used method for such applications depends on model-based inversion with underlying assumptions on particle properties. Furthermore, the presence of sampling biases such as velocity differentials are often overlooked by the simple ex-situ calibrations, which introduces as an additional source of error. In contrast, digital inline holography (DIH), a single camera coherent imaging technique, can both measure particle size distributions without the need for a model-based inversion and can directly provide information on the shape characteristics of the particles. In this study, we evaluate the performance of an LD system in characterizing polydisperse droplets produced in a flat fan spray using in-situ DIH based imaging as a reference. The systematic differences in the two techniques are examined. A droplet-trajectory-based correction for the LD-inferred size distributions is proposed to compensate for the observed differences. We validate the correction using NIST standard polydisperse particles undergoing differential settling, and then apply the correction to polydisperse spray droplet measurements. The correction improves agreement between LD and DIH size distributions for droplets over two orders of magnitude, but with LD still underestimating the fraction of droplets at sizes above ~1 mm. This underestimation is possibly linked to the complex oscillatory and rotational motion of droplets which cannot be faithfully captured by measurement or modelled by the correction algorithm without additional information.

[8]  arXiv:2004.00923 (cross-list from physics.med-ph) [pdf, other]
Title: Real-time digital holography of the retina by principal component analysis
Subjects: Medical Physics (physics.med-ph); Image and Video Processing (eess.IV); Instrumentation and Detectors (physics.ins-det); Optics (physics.optics)

We demonstrate the feasibility of high-quality digital holography of the human retina in real-time with a fast camera and commodity computer hardware. High throughput rendering of digital Fresnel holograms from optically-acquired inline interferograms is performed in conjunction with temporal demodulation by projection of hologram sequences onto a data-derived basis in order to discriminate local narrowband coherent detection contrasts, mostly due to blood flow and optical absorption, from spurious interferometric contributions. Digital holograms are calculated from a sustained input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 500 frames per second, processed by principal component analysis. This temporal signal demodulation scheme consists in the projection of stacks of 32 consecutive holograms onto a basis calculated by eigendecomposition of the matrix of their time-lagged covariance; it is performed up to 20 times per second with commodity computer hardware.

[9]  arXiv:2004.01165 (cross-list from nucl-ex) [pdf, other]
Title: A Comment on "The possible explanation of neutron lifetime beam anomaly" by A. P. Serebrov, et al
Subjects: Nuclear Experiment (nucl-ex); Instrumentation and Detectors (physics.ins-det)

We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment

Replacements for Fri, 3 Apr 20

[10]  arXiv:1912.11042 (replaced) [pdf]
Title: First investigation of the response of solar cells to heavy ions above 1 AMeV
Comments: 13 pages, 14 figures
Subjects: Instrumentation and Detectors (physics.ins-det); Nuclear Experiment (nucl-ex)
[11]  arXiv:2003.12678 (replaced) [pdf, other]
Title: A Search for Charged Lepton Flavor Violation in the Mu2e Experiment
Comments: 23 pages, 14 figures. Pre-print of review article submitted to Modern Physics Letters A
Subjects: High Energy Physics - Experiment (hep-ex); Instrumentation and Detectors (physics.ins-det)
[ total of 11 entries: 1-11 ]
[ showing up to 2000 entries per page: fewer | more ]

Disable MathJax (What is MathJax?)

Links to: arXiv, form interface, find, physics, recent, 2004, contact, help  (Access key information)