We gratefully acknowledge support from
the Simons Foundation and member institutions.

Instrumentation and Detectors

New submissions

[ total of 9 entries: 1-9 ]
[ showing up to 2000 entries per page: fewer | more ]

New submissions for Fri, 24 Jun 22

[1]  arXiv:2206.11427 [pdf]
Title: Neutron Interferometry Using a Single Modulated Phase Grating
Comments: This manuscript is submitted to Physical Review A June 2022
Subjects: Instrumentation and Detectors (physics.ins-det); Optics (physics.optics)

Neutron grating interferometry provides information on phase and small-angle scatter in addition to attenuation. Previously, phase grating moir\'e interferometers (PGMI) with two or three phase gratings have been developed. These phase-grating systems use the moir\'e far-field technique to avoid the need for high-aspect absorption gratings used in Talbot-Lau interferometers (TLI) which reduce the neutron flux reaching the detector. We demonstrate through simulations a novel phase grating interferometer system for cold neutrons that requires a single modulated phase grating (MPG) for phase-contrast imaging, as opposed to the two or three phase gratings in previously employed PGMI systems. We compare the MPG system to experiments in the literature that use a two-phase-grating-based PGMI with best-case visibility of around 39% (Pushin et al. 2017). The simulations of the MPG system show improved visibility in comparison to that two-phase-grating-based PGMI. For example, an MPG with a modulation period of 120 micron, pitch of 1 micron, and grating heights with a phase modulation of (${\pi}$,${\pi}/4$), illuminated by a monochromatic beam, produces visibility of 85% with a comparable source-to-detector distance (SDD) as the two-phase-grating-based PGMI. Phase sensitivity, another important performance metric of the grating interferometer was compared to values available in the literature, viz. the conventional TLI with phase sensitivity of 4.5 x 10^3 for an SDD of 3.5 m and a beam wavelength of 0.44 nm (Kim et al. 2014). For a range of modulation periods, the MPG system provides comparable or greater theoretical maximum phase sensitivity of 4.1 x 10^3 to 10.0 x 10^3 for SDDs of up to 3.5 m. This proposed MPG system appears capable of providing high-performance PGMI that obviates the need for the alignment of 2 phase gratings.

[2]  arXiv:2206.11648 [pdf, other]
Title: The Silicon Vertex Detector of the Belle II Experiment
Authors: Laura Zani
Journal-ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 1038, 2022, 166952, ISSN 0168-9002
Subjects: Instrumentation and Detectors (physics.ins-det); High Energy Physics - Experiment (hep-ex)

Since the start of data taking in spring 2019 at the SuperKEKB collider (KEK, Japan) the Belle II Silicon Vertex Detector (SVD) has been operating reliably and with high efficiency, while providing high quality data: high signal-to-noise ratio, greater than 99% hit efficiency, and precise spatial resolution. These attributes, combined with stability over time, result in good tracking efficiency. Currently the occupancy, dominated by beam-background hits, is quite low (about 0.5% in the innermost layer), causing no problems to the SVD data reconstruction. In view of the operation at higher luminosity foreseen in the next years, specific strategies aiming to preserve the tracking performance have been developed and tested on data. The time stability of the trigger allows reducing sampling of the strip-amplifier waveform. The good hit-time resolution can be exploited to further improve the robustness against the higher level of beam background. First effects of radiation damage on strip noise, sensor currents and depletion voltage have been measured: they do not have any detrimental effect on the performance of the detector. Furthermore, no damage to the SVD is observed after sudden and intense bursts of radiation due to beam losses.

[3]  arXiv:2206.11698 [pdf, other]
Title: Feature Extraction Algorithms for Short Preamplifier Transients
Authors: Holger Flemming
Subjects: Instrumentation and Detectors (physics.ins-det)

In this work the extraction of pulse time and amplitude from short pulse transients is analysed as they are recorded by a transient recorder ASIC called ATR16. Algorithms of different complexity are tested with simulated preamplifier data processed with a VHDL model of the ATR16 ASIC. It is shown that a time precision below 1 ns and a signal amplitude precision below 1 MeV energy equivalent is feasible.

[4]  arXiv:2206.11838 [pdf, other]
Title: Quality Control of Image Sensors using Gaseous Tritium Light Sources
Comments: 17 pages, 6 figures, 2 tables. Supplementary material is available at this https URL . 3D files for the printed parts of the calibration source, as well as assembly instructions, are available at: this https URL
Journal-ref: Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences 380, 20210130 (2022)
Subjects: Instrumentation and Detectors (physics.ins-det); Optics (physics.optics)

We propose a practical method for radiometrically calibrating cameras using widely available gaseous tritium light sources (betalights). Along with the gain(conversion factor) and read noise level, the predictable photon flux of the source allows us to gauge the quantum effciency. The design is easily reproducible with a 3D printer and three inexpensive parts. Suitable for common image sensors, we believe that the method has the potential to be a useful tool in microscopy facilities and optical labs alike.

Cross-lists for Fri, 24 Jun 22

[5]  arXiv:2206.11441 (cross-list from physics.comp-ph) [pdf, other]
Title: Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database
Comments: 12 pages, 7 tables, 7 figures
Journal-ref: IEEE Transactions on Nuclear Science, 2022
Subjects: Computational Physics (physics.comp-ph); Nuclear Experiment (nucl-ex); Instrumentation and Detectors (physics.ins-det)

Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with the highest chance of being present in a sample are placed at the top. A metric to evaluate the performance of the different criteria is introduced and used to compare them. Two of the criteria are found to be superior than the others: one based on fuzzy logic, and another that makes use of the gamma relative emission probabilities. A program called histoGe implements these criteria using a SQLite database containing the gamma-lines of isotopes which was parsed from WWW Table of Radioactive Isotopes. histoGe is Free Software and is provided along with the database so they can be used to analyze spectra obtained with generic gamma-ray detectors.

[6]  arXiv:2206.11535 (cross-list from cs.DC) [pdf, other]
Title: Online Event Selection for Mu3e using GPUs
Comments: 8 pages, to be published in IEEE ISPDC 2022 conference proceedings
Subjects: Distributed, Parallel, and Cluster Computing (cs.DC); Instrumentation and Detectors (physics.ins-det)

In the search for physics beyond the Standard Model the Mu3e experiment tries to observe the lepton flavor violating decay $\mu^+ \rightarrow e^+ e^- e^+$. By observing the decay products of $1 \cdot 10^8\mu$/s it aims to either observe the process, or set a new upper limit on its estimated branching ratio. The high muon rates result in high data rates of $80$\,Gbps, dominated by data produced through background processes. We present the Online Event Selection, a three step algorithm running on the graphics processing units (GPU) of the $12$ Mu3e filter farm computers.
By using simple and fast geometric selection criteria, the algorithm first reduces the amount of possible event candidates to below $5\%$ of the initial set. These candidates are then used to reconstruct full particle tracks, correctly reconstructing over $97\%$ of signal tracks. Finally a possible decay vertex is reconstructed using simple geometric considerations instead of a full reconstruction, correctly identifying over $94\%$ of signal events.
We also present a full implementation of the algorithm, fulfilling all performance requirements at the targeted muon rate and successfully reducing the data rate by a factor of $200$.

[7]  arXiv:2206.11554 (cross-list from astro-ph.IM) [pdf, other]
Title: CONCERTO : Digital processing for finding and tuning LEKIDs
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM); Instrumentation and Detectors (physics.ins-det)

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are superconducting microwave resonators able to detect the incoming light at millimeter wavelengths and they are well adapted for frequency multiplexing (currently up to 360 pixels on a single microwave guide). Nevertheless, their use for astronomical observations requires specific readout and acquisition systems both to deal with the instrumental and multiplexing complexity, and to adapt to the observational requirements (e.g. fast sampling rate, background variations, on-line calibration, photometric accuracy, etc). This paper presents the different steps of treatment from identifying the resonance frequency of each LEKID to the continuous automatic control of drifting LEKID resonance frequencies induced by background variations.

Replacements for Fri, 24 Jun 22

[8]  arXiv:2204.04131 (replaced) [pdf]
Title: Tunnel configurations and seismic isolation optimization in underground gravitational wave detectors
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM); Instrumentation and Detectors (physics.ins-det)
[9]  arXiv:2206.04032 (replaced) [pdf, other]
Title: Photocounting statistics of superconducting nanowire single-photon detectors
Comments: 16 pages, 5 figures
Journal-ref: Phys. Rev. A 105, 063716 (2022)
Subjects: Quantum Physics (quant-ph); Instrumentation and Detectors (physics.ins-det)
[ total of 9 entries: 1-9 ]
[ showing up to 2000 entries per page: fewer | more ]

Disable MathJax (What is MathJax?)

Links to: arXiv, form interface, find, physics, recent, 2206, contact, help  (Access key information)