Instrumentation and Detectors

New submissions

[ total of 8 entries: 1-8 ]
[ showing up to 2000 entries per page: fewer | more ]

New submissions for Thu, 9 Jul 20

[1]  arXiv:2007.03756 [pdf]
Title: A layered single-side readout DOI TOF-PET detector
Subjects: Instrumentation and Detectors (physics.ins-det); Medical Physics (physics.med-ph)

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative offset, with inherent DOI information but good timing performance has not been shown with conventional light sharing readout. 2) Single crystal array with one-to-one coupling to the photodetector (PD) array, with good timing performance, but no DOI. We believe the combination, where the first layer of a staggered design is coupled one-to-one to a PD array may provide both DOI and timing. The concept is here evaluated through light transport simulations. Results show that: 1) In terms of DOI one-to-one readout of the first layer allows for accurate DOI extraction using a single threshold relative to the PD sum signal, for up to 4 layers. The number of PD pixels exceeding the threshold corresponds to the layer of interaction. The corresponding approach is not possible for the same geometries with a light sharing readout scheme. 2) When employing a low threshold of 2 optical photons the layered approach with one-to-one readout of the first layer improves timing close to the PD compared to single layer, due to reduced crystal thickness. Single detector timing resolution values of 91, 127, 151 and 164 ps were seen in the 4-layer design with unpolished pixels, compared to 148 ps for single array with one-to-one coupling. 3) For the layered design with light sharing readout, timing improves with increased PD pixel size, with an apparent tradeoff between spatial resolution and timing not observed for the one-to-one coupled counterpart. The combination of straightforward and accurate DOI determination, good timing performance and relatively simple design makes the proposed detector a promising candidate for brain dedicated DOI TOF-PET.

[2]  arXiv:2007.03921 [pdf, other]
Title: Light simulation in plastic scintillator strip with embedded wavelength shifting fiber
Authors: Zafar Usubov
Comments: 10 pages, 10 figures
Subjects: Instrumentation and Detectors (physics.ins-det)

The simulation study of the light yield and attenuation in the plastic scintillator was performed. The wavelength shifting fiber readout was embedded in the grooves machined along the entire strip surface. The scintillator strips was irradiated with a radiation source {}^{90}Sr or cosmic muons along and across the strip.

[3]  arXiv:2007.04201 [pdf, other]
Title: Charge collection efficiency in back-illuminated Charge-Coupled Devices
Subjects: Instrumentation and Detectors (physics.ins-det); High Energy Physics - Experiment (hep-ex)

Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the performance of future experiments. We present here a new technique to characterize CCE in back-illuminated CCDs based on soft X-rays. This technique is used to characterize two different detector designs. The results demonstrate the importance of the backside processing for detection near threshold, showing that a recombination layer of a few microns significantly distorts the low energy spectrum. The studies demonstrate that the region of partial charge collection can be reduced to less than 1 micrometer thickness with adequate backside processing.

Cross-lists for Thu, 9 Jul 20

[4]  arXiv:2007.04139 (cross-list from astro-ph.IM) [pdf, other]
Title: Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope
Comments: Accepted for publication in JINST
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM); Instrumentation and Detectors (physics.ins-det)

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

[5]  arXiv:2007.04279 (cross-list from physics.optics) [pdf, other]
Title: Optomechanical sensing in the nonlinear saturation limit
Comments: research article, 12 pages, 11 figures
Subjects: Optics (physics.optics); Instrumentation and Detectors (physics.ins-det)

Photonic sensors based upon high-quality optical microcavities have found a wide variety of applications ranging from inertial sensing, electro- and magnetometry to chemical and biological sensing. These sensors have a dynamic range limited by the linewidth of the cavity mode transducing the input. This dynamic range not only determines the range of the signal strength that can be detected, but also affects the resilience of the sensor to large deteriorating external perturbations and shocks in a practical environment. Unfortunately, there is a general trade-off between the detection sensitivity and the dynamic range, which undermines the performance of all microcavity-based sensors. Here we propose an approach to extend the dynamic range significantly beyond the cavity linewidth limit, in the nonlinear modulation regime, without degrading the detection sensitivity for weak signals. With a cavity optomechanical system, we experimentally demonstrate a dynamic range six times larger than the cavity linewidth, far beyond the conventional linear region of operation for such a sensor. The approach demonstrated here will help design microcavity-based sensors to achieve high detection sensitivity and a large dynamic range at the same time, a crucial property for their use in a practical environment.

Replacements for Thu, 9 Jul 20

[6]  arXiv:2001.07821 (replaced) [pdf, ps, other]
Title: First demonstration of a cryocooler conduction cooled superconducting radiofrequency cavity operating at practical cw accelerating gradients
Journal-ref: Supercond. Sci. Technol. 33 06LT01 (2020)
Subjects: Instrumentation and Detectors (physics.ins-det); Accelerator Physics (physics.acc-ph)
[7]  arXiv:2004.05066 (replaced) [pdf, other]
Title: Effects of misalignment on response uniformity of SiPM-on-tile technology for highly granular calorimeters
Comments: 15 pages, 11 figures, 2 tables, v3 version published in JINST
Journal-ref: JINST 15 (2020) P06030
Subjects: Instrumentation and Detectors (physics.ins-det)
[8]  arXiv:2005.07193 (replaced) [pdf, ps, other]
Title: A fully automated dual-tip scanning near-field optical microscope for localized optical excitation and detection in the visible and near-infrared
Journal-ref: Review of Scientific Instruments 90, 053705 (2019)
Subjects: Instrumentation and Detectors (physics.ins-det); Optics (physics.optics)
[ total of 8 entries: 1-8 ]