Medical Physics

New submissions

[ total of 5 entries: 1-5 ]
[ showing up to 2000 entries per page: fewer | more ]

New submissions for Thu, 9 Jul 20

[1]  arXiv:2007.04018 [pdf, other]
Title: Simultaneous Estimation of X-ray Back-Scatter and Forward-Scatter using Multi-Task Learning
Comments: 10 pages, 3 figures, 1 table, accepted at MICCAI 2020
Subjects: Medical Physics (physics.med-ph); Machine Learning (cs.LG); Image and Video Processing (eess.IV)

Scattered radiation is a major concern impacting X-ray image-guided procedures in two ways. First, back-scatter significantly contributes to patient (skin) dose during complicated interventions. Second, forward-scattered radiation reduces contrast in projection images and introduces artifacts in 3-D reconstructions. While conventionally employed anti-scatter grids improve image quality by blocking X-rays, the additional attenuation due to the anti-scatter grid at the detector needs to be compensated for by a higher patient entrance dose. This also increases the room dose affecting the staff caring for the patient. For skin dose quantification, back-scatter is usually accounted for by applying pre-determined scalar back-scatter factors or linear point spread functions to a primary kerma forward projection onto a patient surface point. However, as patients come in different shapes, the generalization of conventional methods is limited. Here, we propose a novel approach combining conventional techniques with learning-based methods to simultaneously estimate the forward-scatter reaching the detector as well as the back-scatter affecting the patient skin dose. Knowing the forward-scatter, we can correct X-ray projections, while a good estimate of the back-scatter component facilitates an improved skin dose assessment. To simultaneously estimate forward-scatter as well as back-scatter, we propose a multi-task approach for joint back- and forward-scatter estimation by combining X-ray physics with neural networks. We show that, in theory, highly accurate scatter estimation in both cases is possible. In addition, we identify research directions for our multi-task framework and learning-based scatter estimation in general.

[2]  arXiv:2007.04282 [pdf]
Title: Hyoscine butylbromide for bowel motion reduction in mouse abdominal MRI
Comments: Carlos Bilreiro and Francisca F. Fernandes contributed equally to this work
Subjects: Medical Physics (physics.med-ph)

Purpose: Bowel motion is a source of artifacts in mouse abdominal MRI. The use of fasting and hyoscine butylbromide (BUSC) for the purpose of bowel motion reduction has been inconsistently reported, without a thorough assessment of efficacy. This work aimed to better evaluate these methods in the mouse with high-field MRI. Methods: Thirty-two adult C57BL/6 mice were imaged in a pre-clinical 9.4T MR scanner. A FLASH sequence with 284 repetitions was used, lasting 90 minutes, with a ~19s temporal resolution. Eight mice were injected with a high-dose and eight mice with a low-dose bolus of BUSC. Eight mice were food deprived for 4.5-6.5 hours and another group of 8 mice were injected with saline. Two readers reviewed the images and classified the magnitude of bowel motion during each scan. Also, the sum of the absolute differences between consecutive images was calculated for 10-11 min intervals throughout the acquisition and mapped voxelwise for identification of moving regions. After defining the most effective protocol, high-resolution T2-weighted and diffusion-weighted images were acquired to demonstrate its applicability. Results: High-dose BUSC was the most effective protocol for bowel motion reduction, for up to 45 min. Fasting and saline effects were negligible. The high-resolution images clearly demonstrate BUSC effectiveness in abdominal MRI. Conclusion: These data favor the use of BUSC for abdominal MRI in the mouse, when bowel motion reduction is desired, taking into account the estimated time interval from injection to start of bowel motion reduction (~8.5 minutes) and duration of effect (~45 minutes).

Cross-lists for Thu, 9 Jul 20

[3]  arXiv:2007.03756 (cross-list from physics.ins-det) [pdf]
Title: A layered single-side readout DOI TOF-PET detector
Subjects: Instrumentation and Detectors (physics.ins-det); Medical Physics (physics.med-ph)

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative offset, with inherent DOI information but good timing performance has not been shown with conventional light sharing readout. 2) Single crystal array with one-to-one coupling to the photodetector (PD) array, with good timing performance, but no DOI. We believe the combination, where the first layer of a staggered design is coupled one-to-one to a PD array may provide both DOI and timing. The concept is here evaluated through light transport simulations. Results show that: 1) In terms of DOI one-to-one readout of the first layer allows for accurate DOI extraction using a single threshold relative to the PD sum signal, for up to 4 layers. The number of PD pixels exceeding the threshold corresponds to the layer of interaction. The corresponding approach is not possible for the same geometries with a light sharing readout scheme. 2) When employing a low threshold of 2 optical photons the layered approach with one-to-one readout of the first layer improves timing close to the PD compared to single layer, due to reduced crystal thickness. Single detector timing resolution values of 91, 127, 151 and 164 ps were seen in the 4-layer design with unpolished pixels, compared to 148 ps for single array with one-to-one coupling. 3) For the layered design with light sharing readout, timing improves with increased PD pixel size, with an apparent tradeoff between spatial resolution and timing not observed for the one-to-one coupled counterpart. The combination of straightforward and accurate DOI determination, good timing performance and relatively simple design makes the proposed detector a promising candidate for brain dedicated DOI TOF-PET.

Replacements for Thu, 9 Jul 20

[4]  arXiv:2007.03645 (replaced) [pdf]
Title: Risk assessment of airborne transmission of COVID-19 by asymptomatic individuals under different practical settings
Comments: 38 pages, 3 main figures, 18 supplementary figures, submitted to Science
Subjects: Medical Physics (physics.med-ph); Fluid Dynamics (physics.flu-dyn)
[5]  arXiv:1912.07197 (replaced) [pdf, other]
Title: Dense Recurrent Neural Networks for Accelerated MRI: History-Cognizant Unrolling of Optimization Algorithms
Journal-ref: IEEE Journal of Selected Topics in Signal Processing, 2020
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Signal Processing (eess.SP); Medical Physics (physics.med-ph)
[ total of 5 entries: 1-5 ]