We gratefully acknowledge support from
the Simons Foundation and member institutions.

Medical Physics

New submissions

[ total of 8 entries: 1-8 ]
[ showing up to 2000 entries per page: fewer | more ]

New submissions for Thu, 13 Jan 22

[1]  arXiv:2201.04415 [pdf, other]
Title: An ultrasonography-based approach for optical diagnostics and phototherapy treatment strategies
Comments: Article accepted in Journal of Biophotonics with title "An ultrasonography-based approach for tissue modelling to inform phototherapy treatment strategies", status: IN PRESS, DOI not generated
Subjects: Medical Physics (physics.med-ph); Biological Physics (physics.bio-ph); Optics (physics.optics)

Currently, diagnostic medicine uses a multitude of tools ranging from ionising radiation to histology analysis. With advances in piezoelectric crystal technology, high-frequency ultrasound imaging has developed to achieve comparatively high resolution without the drawbacks of ionising radiation. This research proposes a low-cost, non-invasive and real-time protocol for informing photo-therapy procedures using ultrasound imaging. We combine currently available ultrasound procedures with Monte Carlo methods for assessing light transport and photo-energy deposition in the tissue. The measurements from high-resolution ultrasound scans is used as input for optical simulations. Consequently, this provides a pipeline that will inform medical practitioners for better therapy strategy planning. While validating known inferences of light transport through biological tissue, our results highlight the range of information such as temporal monitoring and energy deposition at varying depths. This process also retains the flexibility of testing various wavelengths for individual-specific geometries and anatomy.

[2]  arXiv:2201.04487 [pdf, other]
Title: Smoothness and continuity of cost functionals for ECG mismatch computation
Subjects: Medical Physics (physics.med-ph); Machine Learning (cs.LG); Signal Processing (eess.SP); Optimization and Control (math.OC)

The field of cardiac electrophysiology tries to abstract, describe and finally model the electrical characteristics of a heartbeat. With recent advances in cardiac electrophysiology, models have become more powerful and descriptive as ever. However, to advance to the field of inverse electrophysiological modeling, i.e. creating models from electrical measurements such as the ECG, the less investigated field of smoothness of the simulated ECGs w.r.t. model parameters need to be further explored. The present paper discusses smoothness in terms of the whole pipeline which describes how from physiological parameters, we arrive at the simulated ECG. Employing such a pipeline, we create a test-bench of a simplified idealized left ventricle model and demonstrate the most important factors for efficient inverse modeling through smooth cost functionals. Such knowledge will be important for designing and creating inverse models in future optimization and machine learning methods.

[3]  arXiv:2201.04556 [pdf, other]
Title: Transport and evaporation of virus-containing droplets exhaled by men and women in typical cough events
Subjects: Medical Physics (physics.med-ph); Fluid Dynamics (physics.flu-dyn)

The spreading of the virus-containing droplets exhaled during respiratory events, e.g., cough, is an issue of paramount importance for the prevention of many infections such as COVID-19. According to the scientific literature, remarkable differences can be ascribed to several parameters that govern such complex and multiphysical problem. Among these, a particular influence appears associated with the different airflows typical of male and female subjects. Focusing on a typical cough event, we investigate this aspect by means of highly-resolved direct numerical simulations of the turbulent airflow in combination with a comprehensive Lagrangian particle tracking model for the droplet motion and evaporation. We observe and quantify major differences between the case of male and female subjects, both in terms of the droplet final reach and evaporation time. Our results can be associated with the different characteristics in the released airflow and thus confirm the influence of the subject gender (or other physical properties providing different exhalation profiles) on both short-range and long-range airborne transmission.

[4]  arXiv:2201.04570 [pdf]
Title: Characterization of a Newly Designed Diode Dosimeter for UHDR FLASH Radiotherapy
Comments: 18 Pages, 7 Figures
Subjects: Medical Physics (physics.med-ph)

Purpose: A newly designed diode EDGE Detector has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry.
Methods: Dose linearity, mean dose rate, and dose per pulse dependencies of the EDGE Detector were quantified and compared with dosimeters including a W1 scintillator detector, radiochromic film, and ionization chamber, irradiated with a 10 MeV UHDR beam. The dose, dose rate and dose per pulse were controlled via an in-house developed scintillation-based feedback mechanism, repetition rate of the linear accelerator, and source-to-surface distance, respectively. Depth-dose profiles and temporal profiles at single pulse resolution were compared to the film and scintillation measurements, respectively. The radiation-induced change in response sensitivity was quantified via irradiation of ~5kGy.
Results: The EDGE Detector agreed with film measurements in the measured range with varying dose (up to 70 Gy), dose rate (nearly 200 Gy/s), and dose per pulse (up to 0.63 Gy/pulse) on average to within 2%, 5%, and 1%, respectively. The EDGE Detector signal was proportional to IC measured dose, and mean dose rate in the bremsstrahlung tail to within 0.4% and 0.2% respectively. The EDGE Detector measured percent depth dose agreed with film to within 3% and per pulse output agreed with W1 scintillator to within 4%. The radiation-induced response decrease was 0.4% per kGy.
Conclusions: The EDGE Detector demonstrated dose linearity, mean dose rate independence, and dose per pulse independence for UHDR electron beams. It can quantify the beam spatially, and temporally at sub millisecond resolution. It's robustness and single pulse detectability of treatment deliveries can potentially lead to its implementation for in vivo FLASH dosimetry, and dose monitoring.

Cross-lists for Thu, 13 Jan 22

[5]  arXiv:2201.04363 (cross-list from eess.IV) [pdf, other]
Title: ALTRUIST: Alternating Direction Method of Multipliers for Total Variation Regularization in Ultrasound Strain Imaging
Subjects: Image and Video Processing (eess.IV); Medical Physics (physics.med-ph)

Ultrasound strain imaging, which delineates mechanical properties to detect tissue abnormalities, involves estimating the time-delay between two radio-frequency (RF) frames collected before and after tissue deformation. The existing regularized optimization-based time-delay estimation (TDE) techniques suffer from at least one of the following drawbacks: 1) The regularizer is not aligned with tissue deformation physics due to taking only the first-order displacement derivative into account. 2) The L2-norm of the displacement derivatives, which oversmoothes the estimated time-delay, is utilized as the regularizer. 3) The absolute value function's sharp corner should be approximated by a smooth function to facilitate the optimization of L1-norm. Herein, to resolve these shortcomings, we propose employing the alternating direction method of multipliers (ADMM) for optimizing a novel cost function consisting of L2-norm data fidelity term, L1-norm first- and second-order spatial continuity terms. ADMM empowers the proposed algorithm to use different techniques for optimizing different parts of the cost function and obtain high-contrast strain images with smooth background and sharp boundaries. We name our technique ADMM for totaL variaTion RegUlarIzation in ultrasound STrain imaging (ALTRUIST). In extensive simulation, phantom, and in vivo experiments, ALTRUIST substantially outperforms GLUE, OVERWIND, and L1-SOUL, three recently-published TDE algorithms, both qualitatively and quantitatively. ALTRUIST yields 89%, 88%, and 26% improvements of contrast-to-noise ratio over L1-SOUL for simulated, phantom, and in vivo liver cancer datasets, respectively. We will publish the ALTRUIST code after the acceptance of this paper at this http URL

[6]  arXiv:2201.04542 (cross-list from math.NA) [pdf, ps, other]
Title: Numerical comparison of iterative and functional-analytical algorithms for inverse acoustic scattering
Authors: A.S. Shurup
Subjects: Numerical Analysis (math.NA); Computational Physics (physics.comp-ph); Medical Physics (physics.med-ph)

In this work the numerical solution of acoustic tomography problem based on the iterative and functional-analytical algorithms is considered. The mathematical properties of these algorithms were previously described in works of R.G.Novikov for the case of the Schr\"odinger equation. In the present work, for the case of two-dimensional scalar Helmholtz equation, the efficiency of the iterative algorithm in reconstruction of middle strength scatterers and advantages of the functional-analytical approach in recovering strong scatterers are demonstrated. A filtering procedure is considered in the space of wave vectors, which additionally increases the convergence of the iterative algorithm. Reconstruction results of sound speed perturbations demonstrate the comparable noise immunity and resolution of the considered algorithms when reconstructing middle strength scatterers. A comparative numerical investigation of the iterative and functional-analytical algorithms in inverse acoustic scattering problems is implemented in this work for the first time.

Replacements for Thu, 13 Jan 22

[7]  arXiv:2112.12196 (replaced) [pdf, other]
Title: Compelling new electrocardiographic markers for automatic diagnosis
Subjects: Medical Physics (physics.med-ph); Quantitative Methods (q-bio.QM); Applications (stat.AP)
[8]  arXiv:2108.07619 (replaced) [pdf, other]
Title: Deep MRI Reconstruction with Radial Subsampling
Comments: 9 pages, 7 figures, 1 table
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Medical Physics (physics.med-ph)
[ total of 8 entries: 1-8 ]
[ showing up to 2000 entries per page: fewer | more ]

Disable MathJax (What is MathJax?)

Links to: arXiv, form interface, find, physics, recent, 2201, contact, help  (Access key information)