We gratefully acknowledge support from
the Simons Foundation and member institutions.

Medical Physics

New submissions

[ total of 8 entries: 1-8 ]
[ showing up to 100 entries per page: fewer | more ]

New submissions for Tue, 27 Sep 22

[1]  arXiv:2209.11803 [pdf]
Title: Compact orthogonal view OCT: clinical exploration of human trabecular meshwork and cornea at cell resolution
Subjects: Medical Physics (physics.med-ph); Optics (physics.optics)

Glaucoma remains among the leading causes of blindness despite many treatment options available today. Effective treatment requires early diagnosis, which is difficult to achieve with existing imaging technologies that detect the already inflicted irreversible posterior eye damage. One improved approach could be to detect the changes in trabecular meshwork of the anterior eye that precede the intraocular pressure buildup and vision loss. Here we report a device that enables in vivo exploration of trabecular meshwork at cell resolution. The instrument combines two orthogonal views: en face view of time-domain full-field OCT for high-resolution and cross-sectional view of spectral-domain OCT for aligning to the meshwork. The device resolves micron-level corneoscleral and uveal pores, meshwork beams and internal elastic fibers, ciliary body tendons and trabecular cell nuclei. Capable of detecting blockage of trabecular pores, orthogonal view OCT presents a promising solution to the long-standing problem of early glaucoma diagnosis. Future clinical adoption of the device is facilitated by the compact footprint and broad functionality that includes corneal imaging in healthy subjects and patients (with keratoconus, Fuchs endothelial dystrophy) using the same design.

[2]  arXiv:2209.12031 [pdf]
Title: Pseudo-CTs from T1-weighted MRI for planning of low-intensity transcranial focused ultrasound neuromodulation: an open-source tool
Authors: Siti Nurbaya Yaakub (1 and 2), Tristan A. White (1), Eric Kerfoot (3), Lennart Verhagen (4), Alexander Hammers (2), Elsa F. Fouragnan (1) ((1) Brain Research & Imaging Centre University of Plymouth, (2) KCL & GSTT PET Centre Kings College London, (3) School of Biomedical Engineering & Imaging Sciences Kings College London, (4) Donders Institute for Brain Cognition & Behaviour Radboud University)
Comments: 24 pages, 4 figures
Subjects: Medical Physics (physics.med-ph)

Background: Individual skull models of bone density and geometry are important when planning the expected transcranial ultrasound acoustic field and estimating mechanical and thermal safety in low-intensity transcranial ultrasound stimulation (TUS) studies. Computed tomography (CT) images have typically been used to estimate skull acoustic properties. However, obtaining CT images in research participants may be prohibitive due to exposure to ionising radiation and limited access to CT scanners within research groups.
Objective: We present a validated open-source tool for researchers to obtain individual skull estimates from T1-weighted MR images, for use in acoustic simulations.
Methods: We refined a previously trained and validated 3D convolutional neural network (CNN) to generate 100 keV pseudo-CTs. The network was pretrained on 110 individuals and refined and tested on a database of 37 healthy control individuals. We compared simulations based on reference CTs to simulations based on our pseudo-CTs and binary skull masks, a common alternative in the absence of CT.
Results: Compared with reference CTs, our CNN produced pseudo-CTs with a mean absolute error of 109.8 +/- 13.0 HU across the whole head and 319.3 +/- 31.9 HU in the skull. In acoustic simulations, the focal pressure was statistically equivalent for simulations based on reference CT and pseudo-CT (0.48 +/- 0.04 MPa and 0.50 +/- 0.04 MPa respectively) but not for binary skull masks (0.28 +/- 0.05 MPa).
Conclusions: We show that our network can produce pseudo-CT comparable to reference CTs in healthy individuals, and that these can be used in acoustic simulations.

[3]  arXiv:2209.12375 [pdf]
Title: Photon-counting CT thermometry via material decomposition and machine learning
Subjects: Medical Physics (physics.med-ph)

Thermal ablation procedures, such as high intensity focused ultrasound (HIFU) and Radiofrequency Ablation (RFA), are often used to eliminate tumors by minimally invasively heating a focal region. For this task, real-time 3D temperature visualization is key to target the diseased tissues while minimizing damage to the surroundings. Current CT thermometry is based on energy-integrated CT, tissue-specific experimental data, and linear relationships between attenuation and temperature. In this letter, we develop a novel approach using photon-counting CT for material decomposition and a neural network to predict temperature based on thermal characteristics of base materials and spectral tomographic measurements of a volume of interest. In our feasibility study, distilled water, 50 mM CaCl2, and 600 mM CaCl2 are chosen as the base materials. Their attenuations are measured in four discrete energy bins at various temperatures. The neural network trained on the experimental data achieves a mean absolute error of 1.80 {\deg}C and 3.97 {\deg}C on 300 mM CaCl2 and a milk-based protein shake respectively. These experimental results indicate that our approach is promising for handling nonlinear thermal properties for materials that are similar or dissimilar to our base materials.

Cross-lists for Tue, 27 Sep 22

[4]  arXiv:2209.12104 (cross-list from eess.IV) [pdf, other]
Title: Conversion Between CT and MRI Images Using Diffusion and Score-Matching Models
Authors: Qing Lyu, Ge Wang
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Medical Physics (physics.med-ph)

MRI and CT are most widely used medical imaging modalities. It is often necessary to acquire multi-modality images for diagnosis and treatment such as radiotherapy planning. However, multi-modality imaging is not only costly but also introduces misalignment between MRI and CT images. To address this challenge, computational conversion is a viable approach between MRI and CT images, especially from MRI to CT images. In this paper, we propose to use an emerging deep learning framework called diffusion and score-matching models in this context. Specifically, we adapt denoising diffusion probabilistic and score-matching models, use four different sampling strategies, and compare their performance metrics with that using a convolutional neural network and a generative adversarial network model. Our results show that the diffusion and score-matching models generate better synthetic CT images than the CNN and GAN models. Furthermore, we investigate the uncertainties associated with the diffusion and score-matching networks using the Monte-Carlo method, and improve the results by averaging their Monte-Carlo outputs. Our study suggests that diffusion and score-matching models are powerful to generate high quality images conditioned on an image obtained using a complementary imaging modality, analytically rigorous with clear explainability, and highly competitive with CNNs and GANs for image synthesis.

[5]  arXiv:2209.12805 (cross-list from physics.soc-ph) [pdf, ps, other]
Title: Medical and economic implications of timely pandemic countermeasures: Generality of the exact solution
Authors: Tsuyoshi Hondou
Comments: 6 pages, 4 figures
Subjects: Physics and Society (physics.soc-ph); Theoretical Economics (econ.TH); Medical Physics (physics.med-ph)

Balancing pandemic control and economics is challenging for sciences, as the numerical analysis assuming specific economic conditions complicates obtaining predictable general findings. In this study, we formulate a theoretical framework and analytically demonstrate that medical effectiveness and economic impact can be reconciled by adopting timely moderate measures. We also explain that this result is a consequence of the general finding of ``economic irreversibility" by comparing it with thermodynamics. A general inequality provides guiding principles on how measures should be implemented.

Replacements for Tue, 27 Sep 22

[6]  arXiv:2204.10252 (replaced) [pdf, other]
Title: Polynomial Preconditioners for Regularized Linear Inverse Problems
Subjects: Medical Physics (physics.med-ph)
[7]  arXiv:1906.10643 (replaced) [pdf, other]
Title: A Review on Deep Learning in Medical Image Reconstruction
Comments: 31 pages, 6 figures. Survey paper. Revise the typo
Journal-ref: J. Oper. Res. Soc. China 8(2020) 311-340
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph)
[8]  arXiv:2203.02535 (replaced) [pdf]
Title: A Semi-Monolithic Detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-Capabilities for Clinical PET Applications
Comments: Accepted by Medical Physics, bibliographic information to follow
Subjects: Instrumentation and Detectors (physics.ins-det); Medical Physics (physics.med-ph)
[ total of 8 entries: 1-8 ]
[ showing up to 100 entries per page: fewer | more ]

Disable MathJax (What is MathJax?)

Links to: arXiv, form interface, find, physics, recent, 2209, contact, help  (Access key information)