We gratefully acknowledge support from
the Simons Foundation and member institutions.

Medical Physics

New submissions

[ total of 10 entries: 1-10 ]
[ showing up to 1000 entries per page: fewer | more ]

New submissions for Wed, 18 May 22

[1]  arXiv:2205.08053 [pdf]
Title: Modeling the impact of spatial oxygen heterogeneity on radiolytic oxygen depletion during FLASH radiotherapy
Comments: Published version
Journal-ref: Physics in Medicine and Biology, 2022
Subjects: Medical Physics (physics.med-ph)

It has been postulated that the delivery of radiotherapy at ultra-high dose rates ("FLASH") reduces normal tissue toxicities by depleting them of oxygen. The fraction of normal tissue and cancer cells surviving radiotherapy depends on dose and oxygen levels in an exponential manner and even a very small fraction of tissue at low oxygen levels can determine radiotherapy response. The effect of FLASH on radiation-induced normal and tumour tissue cell killing was studied by simulating oxygen diffusion, metabolism, and radiolytic oxygen depletion over domains with simulated capillary architectures. Two architectural models were used: 1.) randomly distributed capillaries and 2.) capillaries forming a regular square lattice array. The resulting oxygen partial pressure distribution histograms were used to simulate normal and tumour tissue cell survival using the linear quadratic model of cell survival, modified to incorporate oxygen-enhancement ratio (OER) effects. Tumour cell survival was found to be increased by FLASH as compared to conventional radiotherapy, with a 0-1 order of magnitude increase for expected levels of tumour hypoxia, depending on the relative magnitudes of radiolytic oxygen depletion and tissue oxygen metabolism. Interestingly, for the random capillary model, the impact of FLASH on well-oxygenated (normal) tissues was found to be much greater, with an estimated increase in cell survival by up to 10 orders of magnitude, even though reductions in mean tissue partial pressure were modest, less than 7 mmHg for the parameter values studied. The presence of very small nearly hypoxic regions in otherwise well-perfused normal tissues with high mean oxygen levels resulted in a greater proportional sparing of normal tissue than tumour cells during FLASH irradiation, possibly explaining empirical normal tissue sparing and iso-tumour control results.

[2]  arXiv:2205.08211 [pdf, other]
Title: Initial non-invasive in vivo sensing of the lung using time domain diffuse optics
Comments: 15 pages, 15 figures, 1 Table
Subjects: Medical Physics (physics.med-ph); Image and Video Processing (eess.IV); Applied Physics (physics.app-ph)

Non-invasive in vivo sensing of the lung with light would help diagnose and monitor pulmonary disorders (caused by e.g. COVID-19, emphysema, immature lung tissue in infants). We investigated the possibility to probe the lung with time domain diffuse optics, taking advantage of the increased depth (few cm) reached by photons detected after a long (few ns) propagation time. An initial study on 5 healthy volunteers included time-resolved broadband diffuse optical spectroscopy measurements at 3 cm source-detector distance over the 600-1100 nm range, and long-distance (6-9 cm) measurements at 820 nm performed during a breathing protocol. The interpretation of the in vivo data with a simplified homogeneous model yielded a maximum probing depth of 2.6-3.9 cm, suitable to reach the lung. Also, signal changes related to the inspiration act were observed, especially at high photon propagation times. Yet, intra- and inter-subject variability and inconsistencies, possibly alluring to competing scattering and absorption effects, prevented a simple interpretation. Aspects to be further investigated to gain a deeper insight are discussed.

[3]  arXiv:2205.08283 [pdf, other]
Title: Towards the optimization of ballistics in proton therapy using genetic algorithms: implementation issues
Comments: 18 pages, 4 figures
Subjects: Medical Physics (physics.med-ph); Neural and Evolutionary Computing (cs.NE)

The dose delivered to the planning target volume by proton beams is highly conformal, sparing organs at risk and normal tissues. New treatment planning systems adapted to spot scanning techniques have been recently proposed to simultaneously optimize several fields and thus improve dose delivery. In this paper, we investigate a new optimization framework based on a genetic algorithm approach. This tool is intended to make it possible to explore new schemes of treatment delivery, possibly with future enhanced technologies. The optimization framework is designed to be versatile and to account for many degrees of freedom, without any {\it a priori} technological constraint. To test the behavior of our algorithm, we propose in this paper, as an example, to optimize beam fluences, target points and irradiation directions at the same time.
The proposed optimization routine takes typically into account several thousands of spots of fixed size. The evolution is carried out by the three standard genetic operators: mutation, crossover and selection. The figure-of-merit (or fitness) is based on an objective function relative to the dose prescription to the tumor and to the limits set for organs at risk and normal tissues. Fluence optimization is carried out via a specific scheme based on a plain gradient with analytical solution. Several specific genetic algorithm issues are addressed: (i) the mutation rate is tuned to balance the search and selection forces, (ii) the initial population is selected using a bootstrap technique and (iii) to scale down the computation time, dose calculations are carried out with a fast analytical ray tracing method and are multi-threaded.
In this paper implementation issues of the optimization framework are thoroughly described. The behavior of the proposed genetic algorithm is illustrated in both elementary and clinically-realistic test cases.

[4]  arXiv:2205.08394 [pdf]
Title: Depth resolved pencil beam radiography using AI -- a proof of principle study
Comments: 10 pages, 6 figures. To be published in Journal of Instrumentation
Subjects: Medical Physics (physics.med-ph); Applied Physics (physics.app-ph); Instrumentation and Detectors (physics.ins-det)

AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission measurements. However, scatter - particularly Compton scatter, is characterizable. In this work we hypothesized that modern radiation sources and detectors paired with deep learning techniques can use scattered photon information constructively to resolve superimposed attenuators in planar x-ray imaging. METHODS: We simulated a monoenergetic x-ray imaging system consisting of a pencil beam x-ray source directed at an imaging target positioned in front of a high spatial- and energy-resolution detector array. The signal was analyzed by a convolutional neural network, and a description of scattering material along the axis of the beam was derived. The system was virtually designed/tested using Monte Carlo processing of simple phantoms consisting of 10 pseudo-randomly stacked air/bone/water materials, and the network was trained by solving a classification problem. RESULTS: The average accuracy of the material identification along the beam was 0.91 +- 0.01, with slightly higher accuracy towards the entrance/exit peripheral surfaces of the object. The average sensitivity and specificity was 0.91 and 0.95, respectively. CONCLUSIONS: Our work provides proof of principle that deep learning techniques can be used to analyze scattered photon patterns which can constructively contribute to the information content in radiography, here used to infer depth information in a traditional 2D planar setup. This principle, and our results, demonstrate that the information in Compton scattered photons may provide a basis for further development. The ability to scale performance to the clinic remains unexplored and requires further study.

[5]  arXiv:2205.08398 [pdf, other]
Title: Variable length genetic algorithm with continuous parameters optimization of beam layout in proton therapy
Comments: 16 pages, 8 figures
Subjects: Medical Physics (physics.med-ph); Neural and Evolutionary Computing (cs.NE)

Proton therapy is a modality in fast development. Characterized by a maximum dose deposition at the end of the proton trajectory followed by a sharp fall-off, proton beams can deliver a highly conformal dose to the tumor while sparing organs at risk and surrounding healthy tissues. New treatment planning systems based on spot scanning techniques can now propose multi-field optimization. However, in most cases, this optimization only processes the field fluences whereas the choice of ballistics (field geometry) is left to the oncologist and medical physicist.
In this work, we investigate a new optimization framework based on a genetic approach. This tool is intended to explore new irradiation schemes and to evaluate the potential of actual or future irradiation systems. We propose to optimize simultaneously the target points and beam incidence angles in a continuous manner and with a variable number of beams. No \textit{a priori} technological constraints are taken into account, \textit{i.e.}~the beam energy values, incidence directions and target points are free parameters.
The proposed algorithm is based on a modified version of classical genetic operators: mutation, crossover and selection. We use the real coding associated with random perturbations of the parameters to obtain a continuous variation of the potential solutions. We also introduce a perturbation in the exchange points of the crossover to allow variations of the number of beams. These variations are controlled by introducing a beam fluence lower limit.
In this paper, we present a complete description of the algorithm and of its behaviour in an elementary test case. The proposed method is finally assessed in a clinically-realistic test case.

[6]  arXiv:2205.08417 [pdf, other]
Title: KiT-RT: An extendable framework for radiative transfer and therapy
Comments: 28 pages, 15 figures, journal submission
Subjects: Medical Physics (physics.med-ph); Mathematical Software (cs.MS)

In this paper we present KiT-RT (Kinetic Transport Solver for Radiation Therapy), an open-source C++ based framework for solving kinetic equations in radiation therapy applications. The aim of this code framework is to provide a collection of classical deterministic solvers for unstructured meshes that allow for easy extendability. Therefore, KiT-RT is a convenient base to test new numerical methods in various applications and compare them against conventional solvers. The implementation includes spherical-harmonics, minimal entropy, neural minimal entropy and discrete ordinates methods. Solution characteristics and efficiency are presented through several test cases ranging from radiation transport to electron radiation therapy. Due to the variety of included numerical methods and easy extendability, the presented open source code is attractive for both developers, who want a basis to build their own numerical solvers and users or application engineers, who want to gain experimental insights without directly interfering with the codebase.

[7]  arXiv:2205.08492 [pdf, other]
Title: Design and Manufacture of Flexible Epidermal NFC Device for Electrochemical Sensing of Sweat
Comments: Accepted for presentation at the 2022 IEEE international conference on Flexible, Printable Sensors and Systems
Subjects: Medical Physics (physics.med-ph); Signal Processing (eess.SP)

Flexible and epidermal sensing devices are becoming vital to enable precision medicine and telemonitoring systems. The NFC (Near Field Communication) protocol is also becoming increasingly important for this application since it is embedded in most smartphones that can be used as pervasive and low-cost readers. Furthermore, the responder can be passive and can harvest enough power to perform electromagnetic sensing. Finally, the NFC coils are robust to bending and to the human body's presence. This contribution details the design of a new flexible device, including an electrochemical sensor communicating through the NFC protocol. A spiral NFC antenna is designed, and a manufactured prototype is experimentally tested to quantify the robustness to the inter-wearer variability and the bending. Lastly, the sensory data retrieval is validated by comparison with a portable potentiostat. The realized sensor can be comfortably worn and be easily read by smartphones independently from the wearer and from the point of application and could be used in future for estimating the user's psycho-physical health by analyzing the body's sweat.

Cross-lists for Wed, 18 May 22

[8]  arXiv:2205.07866 (cross-list from eess.IV) [pdf, ps, other]
Title: Primal-Dual UNet for Sparse View Cone Beam Computed Tomography Volume Reconstruction
Comments: 3 pages, 1 figure, accepted short paper submission at MIDL 2022
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph)

In this paper, the Primal-Dual UNet for sparse view CT reconstruction is modified to be applicable to cone beam projections and perform reconstructions of entire volumes instead of slices. Experiments show that the PSNR of the proposed method is increased by 10dB compared to the direct FDK reconstruction and almost 3dB compared to the modified original Primal-Dual Network when using only 23 projections. The presented network is not optimized wrt. memory consumption or hyperparameters but merely serves as a proof of concept and is limited to low resolution projections and volumes.

[9]  arXiv:2205.07888 (cross-list from eess.IV) [pdf, other]
Title: Data-Driven Interpolation for Super-Scarce X-Ray Computed Tomography
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph)

We address the problem of reconstructing X-Ray tomographic images from scarce measurements by interpolating missing acquisitions using a self-supervised approach. To do so, we train shallow neural networks to combine two neighbouring acquisitions into an estimated measurement at an intermediate angle. This procedure yields an enhanced sequence of measurements that can be reconstructed using standard methods, or further enhanced using regularisation approaches.
Unlike methods that improve the sequence of acquisitions using an initial deterministic interpolation followed by machine-learning enhancement, we focus on inferring one measurement at once. This allows the method to scale to 3D, the computation to be faster and crucially, the interpolation to be significantly better than the current methods, when they exist. We also establish that a sequence of measurements must be processed as such, rather than as an image or a volume. We do so by comparing interpolation and up-sampling methods, and find that the latter significantly under-perform.
We compare the performance of the proposed method against deterministic interpolation and up-sampling procedures and find that it outperforms them, even when used jointly with a state-of-the-art projection-data enhancement approach using machine-learning. These results are obtained for 2D and 3D imaging, on large biomedical datasets, in both projection space and image space.

[10]  arXiv:2205.08123 (cross-list from eess.IV) [pdf]
Title: Using artificial intelligence to detect chest X-rays with no significant findings in a primary health care setting in Oulu, Finland
Comments: Abstract #21318 - ECR 2022 oral presentations
Subjects: Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Medical Physics (physics.med-ph)

Objectives: To assess the use of artificial intelligence-based software in ruling out chest X-ray cases, with no significant findings in a primary health care setting.
Methods: In this retrospective study, a commercially available artificial intelligence (AI) software was used to analyse 10 000 chest X-rays of Finnish primary health care patients. In studies with a mismatch between an AI normal report and the original radiologist report, a consensus read by two board-certified radiologists was conducted to make the final diagnosis.
Results: After the exclusion of cases not meeting the study criteria, 9579 cases were analysed by AI. Of these cases, 4451 were considered normal in the original radiologist report and 4644 after the consensus reading. The number of cases correctly found nonsignificant by AI was 1692 (17.7% of all studies and 36.4% of studies with no significant findings). After the consensus read, there were nine confirmed false-negative studies. These studies included four cases of slightly enlarged heart size, four cases of slightly increased pulmonary opacification and one case with a small unilateral pleural effusion. This gives the AI a sensitivity of 99.8% (95% CI= 99.65-99.92) and specificity of 36.4 % (95% CI= 35.05-37.84) for recognising significant pathology on a chest X-ray.
Conclusions: AI was able to correctly rule out 36.4% of chest X-rays with no significant findings of primary health care patients, with a minimal number of false negatives that would lead to effectively no compromise on patient safety. No critical findings were missed by the software.

[ total of 10 entries: 1-10 ]
[ showing up to 1000 entries per page: fewer | more ]

Disable MathJax (What is MathJax?)

Links to: arXiv, form interface, find, physics, recent, 2205, contact, help  (Access key information)