We gratefully acknowledge support from
the Simons Foundation and member institutions.

Medical Physics

New submissions

[ total of 4 entries: 1-4 ]
[ showing up to 500 entries per page: fewer | more ]

New submissions for Fri, 1 Jul 22

[1]  arXiv:2206.15384 [pdf, other]
Title: A data-driven Reduced Order Method for parametric optimal blood flow control: application to coronary bypass graft
Subjects: Medical Physics (physics.med-ph); Computational Engineering, Finance, and Science (cs.CE)

We consider an optimal flow control problem in a patient-specific coronary artery bypass graft with the aim of matching the blood flow velocity with given measurements as the Reynolds number varies in a physiological range. Blood flow is modelled with the steady incompressible Navier-Stokes equations. The geometry consists in a stenosed left anterior descending artery where a single bypass is performed with the right internal thoracic artery. The control variable is the unknown value of the normal stress at the outlet boundary, which is need for a correct set-up of the outlet boundary condition. For the numerical solution of the parametric optimal flow control problem, we develop a data-driven reduced order method that combines proper orthogonal decomposition (POD) with neural networks. We present numerical results showing that our data-driven approach leads to a substantial speed-up with respect to a more classical POD-Galerkin strategy proposed in [59], while having comparable accuracy.

[2]  arXiv:2206.15441 [pdf, other]
Title: Classical and learned MR to pseudo-CT mappings for accurate transcranial ultrasound simulation
Subjects: Medical Physics (physics.med-ph); Machine Learning (cs.LG)

Model-based treatment planning for transcranial ultrasound therapy typically involves mapping the acoustic properties of the skull from an x-ray computed tomography (CT) image of the head. Here, three methods for generating pseudo-CT images from magnetic resonance (MR) images were compared as an alternative to CT. A convolutional neural network (U-Net) was trained on paired MR-CT images to generate pseudo-CT images from either T1-weighted or zero-echo time (ZTE) MR images (denoted tCT and zCT, respectively). A direct mapping from ZTE to pseudo-CT was also implemented (denoted cCT). When comparing the pseudo-CT and ground truth CT images for the test set, the mean absolute error was 133, 83, and 145 Hounsfield units (HU) across the whole head, and 398, 222, and 336 HU within the skull for the tCT, zCT, and cCT images, respectively. Ultrasound simulations were also performed using the generated pseudo-CT images and compared to simulations based on CT. An annular array transducer was used targeting the visual or motor cortex. The mean differences in the simulated focal pressure, focal position, and focal volume were 9.9%, 1.5 mm, and 15.1% for simulations based on the tCT images, 5.7%, 0.6 mm, and 5.7% for the zCT, and 6.7%, 0.9 mm, and 12.1% for the cCT. The improved results for images mapped from ZTE highlight the advantage of using imaging sequences which improve contrast of the skull bone. Overall, these results demonstrate that acoustic simulations based on MR images can give comparable accuracy to those based on CT.

Cross-lists for Fri, 1 Jul 22

[3]  arXiv:2206.15106 (cross-list from physics.geo-ph) [pdf, other]
Title: Sink versus tilt penetration into shaken dry granular matter: The role of the foundation
Comments: arXiv admin note: substantial text overlap with arXiv:1605.08024
Journal-ref: Physical Review E , American Physical Society (APS), 2022, 105 (2), pp.024903
Subjects: Geophysics (physics.geo-ph); Medical Physics (physics.med-ph)

We study the behavior of cylindrical objects as they sink into a drygranular bed fluidized due to lateral oscillations. Somewhat unexpectedly, we have found that, within a large range of lateral shaking powers,cylinders with flat bottoms sink vertically, while those with a''foundation'' consisting in ashallow ring attached to their bottom, tilt besides sinking. Thelatter scenario seems to dominate independently from the nature ofthe foundation when strong enough lateral vibrations are applied. Weare able to explain the observed behavior by quasi-2D numericalsimulations, which also demonstrate the influence of the intruder's aspect ratio. The vertical sink dynamics is explained with the help of a Newtonian equation of motion for the intruder. Our findings may shed light on the behavior of buildings and other man-made constructions during earthquakes.

Replacements for Fri, 1 Jul 22

[4]  arXiv:2206.03820 (replaced) [pdf, ps, other]
Title: SUPER-IVIM-DC: Intra-voxel incoherent motion based Fetal lung maturity assessment from limited DWI data using supervised learning coupled with data-consistency
Comments: Accepted to the International Conference on Medical Image Computing and Computer Assisted Intervention - MICCAI 2022, to be held during Sept 18-22 in Singapore
Subjects: Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Image and Video Processing (eess.IV); Medical Physics (physics.med-ph)
[ total of 4 entries: 1-4 ]
[ showing up to 500 entries per page: fewer | more ]

Disable MathJax (What is MathJax?)

Links to: arXiv, form interface, find, physics, recent, 2207, contact, help  (Access key information)