Current browse context:
cond-mat.mtrl-sci
Change to browse by:
References & Citations
Condensed Matter > Materials Science
Title: Local probing of the field emission stability of vertically aligned multiwalled carbon nanotubes
(Submitted on 29 Feb 2008)
Abstract: Metallic cantilever in high vacuum atomic force microscope has been used as anode for field emission experiments from densely packed vertically aligned multi-walled carbon nanotubes. The high spatial resolution provided by the scanning probe technique allowed precise setting of the tip-sample distance in the submicron region. The dimension of the probe (curvature radius below 50nm) allowed to measure current contribution from sample areas smaller than 1um^2. The study of long-term stability evidenced that on these small areas the field emission current remains stable (within 10% fluctuations) several hours (at least up to 72 hours) at current intensities between 10-5A and 10-8A. Improvement of the current stability has been observed after performing long-time Joule heating conditioning to completely remove possible adsorbates on the nanotubes.
Submission history
From: Filippo Giubileo Dr [view email][v1] Fri, 29 Feb 2008 13:53:18 GMT (670kb)
Link back to: arXiv, form interface, contact.