We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

astro-ph.IM

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Astrophysics > Instrumentation and Methods for Astrophysics

Title: The LOFAR long baseline snapshot calibrator survey

Authors: J. Moldón, A. T. Deller, O. Wucknitz, N. Jackson, A. Drabent, T. Carozzi, J. Conway, A. D. Kapińska, P. McKean, L. Morabito, E. Varenius, P. Zarka, J. Anderson, A. Asgekar, I. M. Avruch, M. E. Bell, M. J. Bentum, G. Bernardi, P. Best, L. Bîrzan, J. Bregman, F. Breitling, J. W. Broderick, M. Brüggen, H. R. Butcher, D. Carbone, B. Ciardi, F. de Gasperin, E. de Geus, S. Duscha, J. Eislöffel, D. Engels, H. Falcke, R. A. Fallows, R. Fender, C. Ferrari, W. Frieswijk, M. A. Garrett, J. Grießmeier, A. W. Gunst, J. P. Hamaker, T. E. Hassall, G. Heald, M. Hoeft, E. Juette, A. Karastergiou, V. I. Kondratiev, M. Kramer, M. Kuniyoshi, G. Kuper, P. Maat, G. Mann, S. Markoff, R. McFadden, D. McKay-Bukowski, R. Morganti, H. Munk, M. J. Norden, A. R. Offringa, E. Orru, H. Paas, et al. (24 additional authors not shown)
Abstract: Aims. An efficient means of locating calibrator sources for International LOFAR is developed and used to determine the average density of usable calibrator sources on the sky for subarcsecond observations at 140 MHz. Methods. We used the multi-beaming capability of LOFAR to conduct a fast and computationally inexpensive survey with the full International LOFAR array. Sources were pre-selected on the basis of 325 MHz arcminute-scale flux density using existing catalogues. By observing 30 different sources in each of the 12 sets of pointings per hour, we were able to inspect 630 sources in two hours to determine if they possess a sufficiently bright compact component to be usable as LOFAR delay calibrators. Results. Over 40% of the observed sources are detected on multiple baselines between international stations and 86 are classified as satisfactory calibrators. We show that a flat low-frequency spectrum (from 74 to 325 MHz) is the best predictor of compactness at 140 MHz. We extrapolate from our sample to show that the density of calibrators on the sky that are sufficiently bright to calibrate dispersive and non-dispersive delays for the International LOFAR using existing methods is 1.0 per square degree. Conclusions. The observed density of satisfactory delay calibrator sources means that observations with International LOFAR should be possible at virtually any point in the sky, provided that a fast and efficient search using the methodology described here is conducted prior to the observation to identify the best calibrator.
Comments: 13 pages, 9 figures. Accepted for publication in Astronomy and Astrophysics
Subjects: Instrumentation and Methods for Astrophysics (astro-ph.IM)
Journal reference: A&A 574, A73 (2015)
DOI: 10.1051/0004-6361/201425042
Cite as: arXiv:1411.2743 [astro-ph.IM]
  (or arXiv:1411.2743v1 [astro-ph.IM] for this version)

Submission history

From: Javier Moldon [view email]
[v1] Tue, 11 Nov 2014 09:39:50 GMT (551kb)

Link back to: arXiv, form interface, contact.