Title: Multi-metallic conduction cooled superconducting radio-frequency cavity with high thermal stability

Authors: G. Ciovati (1 and 2), G. Cheng (1), U. Pudasaini (3), R. Rimmer (1) ((1) Thomas Jefferson National Accelerator Facility, (2) Center for Accelerator Science, Department of Physics, Old Dominion University, (3) The College of William & Mary)
Abstract: Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and are cooled by a liquid helium bath at a temperature of ~2 K. The size, cost and complexity of operating a particle accelerator with a liquid helium refrigerator makes the current cavity technology not favorable for use in industrial-type accelerators. We developed a multi-metallic 1.495~GHz elliptical cavity conductively cooled by a cryocooler. The cavity has a ~2 $\mu$m thick layer of Nb$_3$Sn on the inner surface, exposed to the rf field, deposited on a ~3 mm thick bulk Nb shell and a bulk Cu shell, of thickness $\geqslant 5$ mm deposited on the outer surface by electroplating. A bolt-on Cu plate 1.27 cm thick was used to thermally connect the cavity equator to the second stage of a Gifford-McMahon cryocooler with a nominal capacity of 2 W at 4.2 K. The cavity was tested initially in liquid helium at 4.3 K and reached a peak surface magnetic field of ~36 mT with a quality factor of $2\times 10^9$. The cavity cooled by the crycooler achieved a peak surface magnetic field of ~29 mT, equivalent to an accelerating gradient of 6.5 MV/m, and it was able to operate in continuous-wave with as high as 5 W dissipation in the cavity for 1 h without any thermal breakdown. This result represents a paradigm shift in the technology of superconducting accelerator cavities.
Subjects: Instrumentation and Detectors (physics.ins-det); Accelerator Physics (physics.acc-ph)
DOI: 10.1088/1361-6668/ab8d98
Cite as: arXiv:2001.10924 [physics.ins-det]
  (or arXiv:2001.10924v2 [physics.ins-det] for this version)

Submission history

From: Gianluigi Ciovati [view email]
[v1] Wed, 29 Jan 2020 16:11:56 GMT (1288kb,D)
[v2] Fri, 31 Jan 2020 19:51:16 GMT (1288kb,D)

Link back to: arXiv, form interface, contact.