Title: Gaussian Processes for real-time 3D motion and uncertainty estimation during MR-guided radiotherapy

Abstract: Respiratory motion during radiotherapy causes uncertainty in the tumor's location, which is typically addressed by an increased radiation area and a decreased dose. As a result, the treatments' efficacy is reduced. The recently proposed hybrid MR-linac scanner holds the promise to efficiently deal with such respiratory motion through real-time adaptive MR-guided radiotherapy (MRgRT). For MRgRT, motion-fields should be estimated from MR-data and the radiotherapy plan should be adapted in real-time according to the estimated motion-fields. All of this should be performed with a total latency of maximally 200 ms, including data acquisition and reconstruction. A measure of confidence in such estimated motion-fields is highly desirable, for instance to ensure the patient's safety in case of unexpected and undesirable motion. In this work, we propose a framework based on Gaussian Processes to infer 3D motion-fields and uncertainty maps in real-time from only three readouts of MR-data. We demonstrated an inference frame rate up to 69 Hz including data acquisition and reconstruction, thereby exploiting the limited amount of required MR-data. Additionally, we designed a rejection criterion based on the motion-field uncertainty maps to demonstrate the framework's potential for quality assurance. The framework was validated in silico and in vivo on healthy volunteer data (n=5) acquired using an MR-linac, thereby taking into account different breathing patterns and controlled bulk motion. Results indicate end-point-errors with a 75th percentile below 1mm in silico, and a correct detection of erroneous motion estimates with the rejection criterion. Altogether, the results show the potential of the framework for application in real-time MR-guided radiotherapy with an MR-linac.
Comments: This manuscript has supplementary files which can be downloaded at this https URL nl/files/index.php/s/scLts9nJYXfbLMx. The files include videos that show reconstructed motion-fields and spatial uncertainty maps. See the Appendix for a description of all individual files
Subjects: Medical Physics (physics.med-ph)
Cite as: arXiv:2204.09873 [physics.med-ph]
  (or arXiv:2204.09873v1 [physics.med-ph] for this version)

Submission history

From: Niek Huttinga [view email]
[v1] Thu, 21 Apr 2022 04:24:47 GMT (36534kb,D)

Link back to: arXiv, form interface, contact.