Title: Operating the GridPix detector with helium-isobutane gas mixtures for a high-precision, low-mass Time Projection Chamber
(Submitted on 5 May 2023 (v1), last revised 8 Sep 2023 (this version, v2))
Abstract: High precision experiments with muons and pions often require tracking charged particles with $O(100~\mu\mathrm{m})$ single-hit resolution, possibly with particle identification capabilities, down to very low momenta ($p \lesssim 100$~MeV/$c$). In such conditions, the particle trajectories are strongly affected by the interaction with the detector material, and the reconstruction of the kinematic observables consequently deteriorates. A good compromise between resolution and material budget can be obtained with a Time Projection Chamber (TPC), if very light gases and a high-granularity readout are used. In this paper, we present a characterization of the GridPix detector in helium-isobutane gas mixtures, within a TPC with 9~cm maximum drift. Measurements of the main electron drift properties for these gas mixtures are also presented.
Submission history
From: Francesco Renga [view email][v1] Fri, 5 May 2023 15:03:07 GMT (14721kb,D)
[v2] Fri, 8 Sep 2023 12:11:47 GMT (14781kb,D)