Current browse context:
physics.ins-det
Change to browse by:
References & Citations
Physics > Instrumentation and Detectors
Title: Scintillator detectors with long WLS fibers and multi-pixel photodiodes
(Submitted on 12 Oct 2011)
Abstract: We have studied the possibility of using Geiger mode multi-pixel photodiodes to read out long scintillator bars with a single wavelength-shifting fiber embedded along the bar. This detector configuration can be used in large volume detectors in future long baseline neutrino oscillation experiments. Prototype bars of 0.7 cm thickness and different widths have been produced and tested using two types of multi-pixel photodiodes: MRS APD (CPTA, Moscow) and MPPC (Hamamatsu). A minimum light yield of 7.2 p.e./MeV was obtained for a 4 cm wide bar.
Link back to: arXiv, form interface, contact.